WEKO3
アイテム
{"_buckets": {"deposit": "727da425-b28c-4a73-a873-2d0cb1f68439"}, "_deposit": {"created_by": 1, "id": "62226", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "62226"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00062226", "sets": ["29"]}, "author_link": ["615209", "615211", "615206", "615210", "615204", "615205", "615208", "615212", "615207"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2007-09-22", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "X-ray CT apparatuses have been developed as one of very effective diagnostic tools, and been evolved from single to multi-detectors, and single to helical type scanning methods. On the contrary, the doses of patients on X-ray CT examinations are obviously higher than those of general radiographies. In recent, X-ray CT apparatuses have been used for chest examinations of mass-screenings in Japan, and the factors influencing doses of patients are concerns on radiation protection. For estimating the differences by the factors such as beam width and pitch etc. quantitatively, the organ doses of X-ray CT examinations for typical three X-ray CT\napparatuses of different manufactures were directly measured by using thermoluminescence dosimeters and an adult anthropomorphic phantom as the values of normalized organ doses per mAs and effective mAs for the factors. The half-value layers (HVLs) of X-ray CT apparatuses were also measured. The differences of organ doses between the highest and lowest were approximately two times. The organ dose variations among manufactures could be explained by the HVLs as one of the reasons. For the same apparatus, the organ doses were different depending on the factor values (Fig. 1 and 2). The result suggests that the organ doses can be different depending on the kinds of apparatuses even though same X-ray CT examinations would be performed.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "Xth EFOMP Congress - Pisa 2007", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Ko, Susumu"}], "nameIdentifiers": [{"nameIdentifier": "615204", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishizawa, Kanae"}], "nameIdentifiers": [{"nameIdentifier": "615205", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Akahane, Keiichi"}], "nameIdentifiers": [{"nameIdentifier": "615206", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fujii, Keisuke"}], "nameIdentifiers": [{"nameIdentifier": "615207", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "615208", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "幸 進", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "615209", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "西澤 かな枝", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "615210", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "赤羽 恵一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "615211", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤井 啓輔", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "615212", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Organ Dose Measurements on X-Ray CT Examinations among Different Kinds of Apparatuses", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Organ Dose Measurements on X-Ray CT Examinations among Different Kinds of Apparatuses"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/62226", "pubdate": {"attribute_name": "公開日", "attribute_value": "2007-10-01"}, "publish_date": "2007-10-01", "publish_status": "0", "recid": "62226", "relation": {}, "relation_version_is_last": true, "title": ["Organ Dose Measurements on X-Ray CT Examinations among Different Kinds of Apparatuses"], "weko_shared_id": -1}
Organ Dose Measurements on X-Ray CT Examinations among Different Kinds of Apparatuses
https://repo.qst.go.jp/records/62226
https://repo.qst.go.jp/records/62226899f7c19-1dad-428d-bb5f-380fbe5a41a4
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-10-01 | |||||
タイトル | ||||||
タイトル | Organ Dose Measurements on X-Ray CT Examinations among Different Kinds of Apparatuses | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Ko, Susumu
× Ko, Susumu× Nishizawa, Kanae× Akahane, Keiichi× Fujii, Keisuke× et.al× 幸 進× 西澤 かな枝× 赤羽 恵一× 藤井 啓輔 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | X-ray CT apparatuses have been developed as one of very effective diagnostic tools, and been evolved from single to multi-detectors, and single to helical type scanning methods. On the contrary, the doses of patients on X-ray CT examinations are obviously higher than those of general radiographies. In recent, X-ray CT apparatuses have been used for chest examinations of mass-screenings in Japan, and the factors influencing doses of patients are concerns on radiation protection. For estimating the differences by the factors such as beam width and pitch etc. quantitatively, the organ doses of X-ray CT examinations for typical three X-ray CT apparatuses of different manufactures were directly measured by using thermoluminescence dosimeters and an adult anthropomorphic phantom as the values of normalized organ doses per mAs and effective mAs for the factors. The half-value layers (HVLs) of X-ray CT apparatuses were also measured. The differences of organ doses between the highest and lowest were approximately two times. The organ dose variations among manufactures could be explained by the HVLs as one of the reasons. For the same apparatus, the organ doses were different depending on the factor values (Fig. 1 and 2). The result suggests that the organ doses can be different depending on the kinds of apparatuses even though same X-ray CT examinations would be performed. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Xth EFOMP Congress - Pisa 2007 | |||||
発表年月日 | ||||||
日付 | 2007-09-22 | |||||
日付タイプ | Issued |