{"_buckets": {"deposit": "9cd9f6f3-c1c6-4859-a337-8bd8c7348fe2"}, "_deposit": {"created_by": 1, "id": "57360", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "57360"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00057360", "sets": ["11"]}, "author_link": ["579724", "579725", "579727", "579726", "579728", "579723"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "55", "bibliographicPageStart": "51", "bibliographicVolumeNumber": "12", "bibliographic_titles": [{"bibliographic_title": "Medical Standard Dose"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Plane-parallel ionization chambers exhibit polarity effects with low energy electron beams in therapeutic electron dosimetry. In this report, the polarity correction factors for ten commercially available plane-parallel ionization chambers were investigated as a function of mean energy. The factors was measured at phantom surface for ten chambers and depths along depth-dose curves for five chambers of nominal 4, 6, 9, 12 and 15 MeV electron beams. The polarity correction factors for all chambers as phantom surface were 0.5% or less in mean electron energy range of 3.5 to 14.7 MeV. The factors for five chambers in water were also shown to increase substantially with mean energy of about 3 MeV or less.", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Fujisaki, Tatsuya"}], "nameIdentifiers": [{"nameIdentifier": "579723", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hiraoka, Takeshi"}], "nameIdentifiers": [{"nameIdentifier": "579724", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Abe, Shinji"}], "nameIdentifiers": [{"nameIdentifier": "579725", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Saitoh, Hidetoshi"}], "nameIdentifiers": [{"nameIdentifier": "579726", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平岡 武", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "579727", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "阿部 慎司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "579728", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Polarity effects of commercially plane-parallel ionization chambers in therapeutic electron dosimetry", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Polarity effects of commercially plane-parallel ionization chambers in therapeutic electron dosimetry"}]}, "item_type_id": "10004", "owner": "1", "path": ["11"], "permalink_uri": "https://repo.qst.go.jp/records/57360", "pubdate": {"attribute_name": "公開日", "attribute_value": "2008-02-08"}, "publish_date": "2008-02-08", "publish_status": "0", "recid": "57360", "relation": {}, "relation_version_is_last": true, "title": ["Polarity effects of commercially plane-parallel ionization chambers in therapeutic electron dosimetry"], "weko_shared_id": -1}
Polarity effects of commercially plane-parallel ionization chambers in therapeutic electron dosimetry
https://repo.qst.go.jp/records/57360
https://repo.qst.go.jp/records/5736083ebdc6d-8fdc-4e19-b7c7-abf4d6ee4f91
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-02-08 | |||||
タイトル | ||||||
タイトル | Polarity effects of commercially plane-parallel ionization chambers in therapeutic electron dosimetry | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Fujisaki, Tatsuya
× Fujisaki, Tatsuya× Hiraoka, Takeshi× Abe, Shinji× Saitoh, Hidetoshi× 平岡 武× 阿部 慎司 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Plane-parallel ionization chambers exhibit polarity effects with low energy electron beams in therapeutic electron dosimetry. In this report, the polarity correction factors for ten commercially available plane-parallel ionization chambers were investigated as a function of mean energy. The factors was measured at phantom surface for ten chambers and depths along depth-dose curves for five chambers of nominal 4, 6, 9, 12 and 15 MeV electron beams. The polarity correction factors for all chambers as phantom surface were 0.5% or less in mean electron energy range of 3.5 to 14.7 MeV. The factors for five chambers in water were also shown to increase substantially with mean energy of about 3 MeV or less. | |||||
書誌情報 |
Medical Standard Dose 巻 12, 号 2, p. 51-55, 発行日 2007-10 |