{"_buckets": {"deposit": "30882606-2594-4cc3-8d63-7d858338e49d"}, "_deposit": {"created_by": 1, "id": "55701", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "55701"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00055701", "sets": ["7"]}, "author_link": ["569977", "569979", "569978", "569976", "569975"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2010-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "7", "bibliographicPageEnd": "844", "bibliographicPageStart": "836", "bibliographicVolumeNumber": "66", "bibliographic_titles": [{"bibliographic_title": "日本放射線技術学会雑誌"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "IR(inversion recovery)法はMRI(magnetic resonance image)がNMR(nuclear magnetic resonance)−CTと呼ばれていた時代からのパルスシーケンスで、主にT1値の測定やT1強調画像を得るために使用されていた。しかし、TR(repetition time)を長く設定するIR法は撮像時間が長くなるため、T1強調画像を得るための手段としてはほとんど使用されなくなった。その後、IR法は脂肪信号を抑制するためのSTIR(short TI inversion、recovery)法に利用されるようになり、また、高速撮像法が開発され長いTRでも撮像時間を短くできるようになったことで、水信号を抑制するためのFLAIR(fluid attenuated inversion recovery)法にも利用されるようになった。これらのシーケンスはパラメータを変更し検査時間の短縮や画質の改善を行うことがあるが、注意しなけれげならない点がいくつかある。日本放射線技術学会第64回北海道部会春季大会においてMR専門委員会は、「おそるべし!!IRバリエーション」と題しMRセミナーを開催した。3名の演者が、IR法の基礎ならびにSTIR、FLAIRのパラメータ設定の考え方や注意点について発表した。 その内容をまとめたので報告する。", "subitem_description_type": "Abstract"}]}, "item_10004_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0369-4305", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "信田, 修壱"}], "nameIdentifiers": [{"nameIdentifier": "569975", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "安田, 浩司"}], "nameIdentifiers": [{"nameIdentifier": "569976", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "尾松, 美香"}], "nameIdentifiers": [{"nameIdentifier": "569977", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中西, 光広"}], "nameIdentifiers": [{"nameIdentifier": "569978", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "尾松 美香", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "569979", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Inversion recovery法の基礎とパラメータ設定の注意点", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Inversion recovery法の基礎とパラメータ設定の注意点"}]}, "item_type_id": "10004", "owner": "1", "path": ["7"], "permalink_uri": "https://repo.qst.go.jp/records/55701", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-09-14"}, "publish_date": "2010-09-14", "publish_status": "0", "recid": "55701", "relation": {}, "relation_version_is_last": true, "title": ["Inversion recovery法の基礎とパラメータ設定の注意点"], "weko_shared_id": -1}
Inversion recovery法の基礎とパラメータ設定の注意点
https://repo.qst.go.jp/records/55701
https://repo.qst.go.jp/records/55701f94ba705-e7d1-4d04-9cd9-1688d02e23a8
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-09-14 | |||||
タイトル | ||||||
タイトル | Inversion recovery法の基礎とパラメータ設定の注意点 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
信田, 修壱
× 信田, 修壱× 安田, 浩司× 尾松, 美香× 中西, 光広× 尾松 美香 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | IR(inversion recovery)法はMRI(magnetic resonance image)がNMR(nuclear magnetic resonance)−CTと呼ばれていた時代からのパルスシーケンスで、主にT1値の測定やT1強調画像を得るために使用されていた。しかし、TR(repetition time)を長く設定するIR法は撮像時間が長くなるため、T1強調画像を得るための手段としてはほとんど使用されなくなった。その後、IR法は脂肪信号を抑制するためのSTIR(short TI inversion、recovery)法に利用されるようになり、また、高速撮像法が開発され長いTRでも撮像時間を短くできるようになったことで、水信号を抑制するためのFLAIR(fluid attenuated inversion recovery)法にも利用されるようになった。これらのシーケンスはパラメータを変更し検査時間の短縮や画質の改善を行うことがあるが、注意しなけれげならない点がいくつかある。日本放射線技術学会第64回北海道部会春季大会においてMR専門委員会は、「おそるべし!!IRバリエーション」と題しMRセミナーを開催した。3名の演者が、IR法の基礎ならびにSTIR、FLAIRのパラメータ設定の考え方や注意点について発表した。 その内容をまとめたので報告する。 | |||||
書誌情報 |
日本放射線技術学会雑誌 巻 66, 号 7, p. 836-844, 発行日 2010-07 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0369-4305 |