WEKO3
アイテム
{"_buckets": {"deposit": "d12d0d69-8c0a-4135-8a2d-c48f8b019eed"}, "_deposit": {"created_by": 1, "id": "55308", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "55308"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00055308", "sets": ["7"]}, "author_link": ["565589", "565591", "565595", "565590", "565596", "565597", "565593", "565592", "565588", "565594"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2002-09", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "465", "bibliographicPageStart": "461", "bibliographic_titles": [{"bibliographic_title": "厚生労働省がん研究助成金による研究報告集"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "悪性腫瘍の病期診断、治療後の再発、治療効果判定におけるポジトロンCT(PET)の臨床的有用性について検討した。11C(炭素)、18F(フッ素)などの陽電子放出核種(positron emitter)を画像化するPET検査は新しい薬剤の合成が容易で、しかも分解能、定量性に優れた美しい画像が得られる。がん細胞のエネルギー源は主にブドウ糖とアミノ酸で、18Fで標識したブドウ糖誘導体(FDG)、11Cで標識したアミノ酸(メチオニン)を投与し撮像した。頭頚部腫瘍でCT/MRIとFDG−PET検査を比較したところリンパ節転移の診断能のみならず、選択的動注化学療法、重粒子線治療患者でもFDG-PETが優れていた。脳腫瘍に対する治療後の再発の有無はCT、MRIでも困難なことも多いが、11Cで標識したメチオニンが役立つ。甲状腺癌患者でもFDG-PETは131Iの集積しない症例で陽性を示すことが多く、201TI検査を省略することができた。診断精度を向上させるために呼吸同期法の開発、新しいPET用製剤の研究開発にも取り組んだ。", "subitem_description_type": "Abstract"}]}, "item_10004_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1346-9169", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "遠藤, 啓吾"}], "nameIdentifiers": [{"nameIdentifier": "565588", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "玉木, 長良"}], "nameIdentifiers": [{"nameIdentifier": "565589", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福田, 寛"}], "nameIdentifiers": [{"nameIdentifier": "565590", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉川, 京燦"}], "nameIdentifiers": [{"nameIdentifier": "565591", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐治, 英郎"}], "nameIdentifiers": [{"nameIdentifier": "565592", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "その他"}], "nameIdentifiers": [{"nameIdentifier": "565593", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "遠藤 啓吾", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "565594", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福田 寛", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "565595", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉川 京燦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "565596", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐治 英郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "565597", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "ポジトロンCTのがん診断への応用及び診断精度向上に関する研究", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "ポジトロンCTのがん診断への応用及び診断精度向上に関する研究"}]}, "item_type_id": "10004", "owner": "1", "path": ["7"], "permalink_uri": "https://repo.qst.go.jp/records/55308", "pubdate": {"attribute_name": "公開日", "attribute_value": "2004-08-26"}, "publish_date": "2004-08-26", "publish_status": "0", "recid": "55308", "relation": {}, "relation_version_is_last": true, "title": ["ポジトロンCTのがん診断への応用及び診断精度向上に関する研究"], "weko_shared_id": -1}
ポジトロンCTのがん診断への応用及び診断精度向上に関する研究
https://repo.qst.go.jp/records/55308
https://repo.qst.go.jp/records/553083aea1eb8-de81-45ba-8307-4183dc520be2
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2004-08-26 | |||||
タイトル | ||||||
タイトル | ポジトロンCTのがん診断への応用及び診断精度向上に関する研究 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
遠藤, 啓吾
× 遠藤, 啓吾× 玉木, 長良× 福田, 寛× 吉川, 京燦× 佐治, 英郎× その他× 遠藤 啓吾× 福田 寛× 吉川 京燦× 佐治 英郎 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 悪性腫瘍の病期診断、治療後の再発、治療効果判定におけるポジトロンCT(PET)の臨床的有用性について検討した。11C(炭素)、18F(フッ素)などの陽電子放出核種(positron emitter)を画像化するPET検査は新しい薬剤の合成が容易で、しかも分解能、定量性に優れた美しい画像が得られる。がん細胞のエネルギー源は主にブドウ糖とアミノ酸で、18Fで標識したブドウ糖誘導体(FDG)、11Cで標識したアミノ酸(メチオニン)を投与し撮像した。頭頚部腫瘍でCT/MRIとFDG−PET検査を比較したところリンパ節転移の診断能のみならず、選択的動注化学療法、重粒子線治療患者でもFDG-PETが優れていた。脳腫瘍に対する治療後の再発の有無はCT、MRIでも困難なことも多いが、11Cで標識したメチオニンが役立つ。甲状腺癌患者でもFDG-PETは131Iの集積しない症例で陽性を示すことが多く、201TI検査を省略することができた。診断精度を向上させるために呼吸同期法の開発、新しいPET用製剤の研究開発にも取り組んだ。 | |||||
書誌情報 |
厚生労働省がん研究助成金による研究報告集 p. 461-465, 発行日 2002-09 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1346-9169 |