WEKO3
アイテム
{"_buckets": {"deposit": "7a7dfc6a-4c76-4319-b71c-8e30e27aa3b1"}, "_deposit": {"created_by": 1, "id": "54681", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "54681"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00054681", "sets": ["2"]}, "author_link": ["558823", "558818", "558819", "558822", "558821", "558825", "558820", "558824"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2016-09", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "14", "bibliographicPageStart": "11", "bibliographic_titles": [{"bibliographic_title": "レーザー学会第495回研究会報告"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Diabetes mellitus concerns more than 415 million people worldwide, with increasing tendency. According to the World Health Organization (WHO), more than 80% of the diabetes-related deaths occur in low- and middle-income countries, making this disease a global challenge. True non-invasive glucose measurements procedures are presently not available to the diabetic patient. There have been many different approaches without useful results. We propose a new concept to measure glucose non-invasively based on a high-power mid-infrared laser. The precision was achieved ±20% in the range from 60 mg/dL to 180 mg/dL of glucose concentrations in vivo monitoring to date. This is in agreement with the requirements of the ISO 15197 standard.", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "山川, 考一"}], "nameIdentifiers": [{"nameIdentifier": "558818", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "青山, 誠"}], "nameIdentifiers": [{"nameIdentifier": "558819", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "赤羽, 温"}], "nameIdentifiers": [{"nameIdentifier": "558820", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小川, 奏"}], "nameIdentifiers": [{"nameIdentifier": "558821", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山川 考一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "558822", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "青山 誠", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "558823", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "赤羽 温", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "558824", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小川 奏", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "558825", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "手のひらサイズの非侵襲血糖値センサーの開発", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "手のひらサイズの非侵襲血糖値センサーの開発"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/54681", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-01-12"}, "publish_date": "2017-01-12", "publish_status": "0", "recid": "54681", "relation": {}, "relation_version_is_last": true, "title": ["手のひらサイズの非侵襲血糖値センサーの開発"], "weko_shared_id": -1}
手のひらサイズの非侵襲血糖値センサーの開発
https://repo.qst.go.jp/records/54681
https://repo.qst.go.jp/records/546814e5fead6-233f-46ff-bf44-c0c4685e5ab4
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-01-12 | |||||
タイトル | ||||||
タイトル | 手のひらサイズの非侵襲血糖値センサーの開発 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
山川, 考一
× 山川, 考一× 青山, 誠× 赤羽, 温× 小川, 奏× 山川 考一× 青山 誠× 赤羽 温× 小川 奏 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Diabetes mellitus concerns more than 415 million people worldwide, with increasing tendency. According to the World Health Organization (WHO), more than 80% of the diabetes-related deaths occur in low- and middle-income countries, making this disease a global challenge. True non-invasive glucose measurements procedures are presently not available to the diabetic patient. There have been many different approaches without useful results. We propose a new concept to measure glucose non-invasively based on a high-power mid-infrared laser. The precision was achieved ±20% in the range from 60 mg/dL to 180 mg/dL of glucose concentrations in vivo monitoring to date. This is in agreement with the requirements of the ISO 15197 standard. | |||||
書誌情報 |
レーザー学会第495回研究会報告 p. 11-14, 発行日 2016-09 |