{"created":"2023-05-15T14:39:50.671345+00:00","id":54681,"links":{},"metadata":{"_buckets":{"deposit":"7a7dfc6a-4c76-4319-b71c-8e30e27aa3b1"},"_deposit":{"created_by":1,"id":"54681","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"54681"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00054681","sets":["2"]},"author_link":["558823","558818","558819","558822","558821","558825","558820","558824"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-09","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"14","bibliographicPageStart":"11","bibliographic_titles":[{"bibliographic_title":"レーザー学会第495回研究会報告"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Diabetes mellitus concerns more than 415 million people worldwide, with increasing tendency. According to the World Health Organization (WHO), more than 80% of the diabetes-related deaths occur in low- and middle-income countries, making this disease a global challenge. True non-invasive glucose measurements procedures are presently not available to the diabetic patient. There have been many different approaches without useful results. We propose a new concept to measure glucose non-invasively based on a high-power mid-infrared laser. The precision was achieved ±20% in the range from 60 mg/dL to 180 mg/dL of glucose concentrations in vivo monitoring to date. This is in agreement with the requirements of the ISO 15197 standard.","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"山川, 考一"}],"nameIdentifiers":[{"nameIdentifier":"558818","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"青山, 誠"}],"nameIdentifiers":[{"nameIdentifier":"558819","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"赤羽, 温"}],"nameIdentifiers":[{"nameIdentifier":"558820","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小川, 奏"}],"nameIdentifiers":[{"nameIdentifier":"558821","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山川 考一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"558822","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"青山 誠","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"558823","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"赤羽 温","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"558824","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小川 奏","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"558825","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"手のひらサイズの非侵襲血糖値センサーの開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"手のひらサイズの非侵襲血糖値センサーの開発"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-01-12"},"publish_date":"2017-01-12","publish_status":"0","recid":"54681","relation_version_is_last":true,"title":["手のひらサイズの非侵襲血糖値センサーの開発"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:58:02.949404+00:00"}