WEKO3
アイテム
{"_buckets": {"deposit": "3649a067-8a19-41ac-876c-0630c96cd84e"}, "_deposit": {"created_by": 1, "id": "54620", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "54620"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00054620", "sets": ["2"]}, "author_link": ["558027", "558030", "558028", "558029", "558025", "558026"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2015-09", "bibliographicIssueDateType": "Issued"}, "bibliographic_titles": [{"bibliographic_title": "HIAT2015 - Proceedings"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Compact ECR ion sources have been developed for high energy carbon-ion radiotherapy (C-ion RT). Three compact ECR ion sources have been developed as the prototype at NIRS. The first ion source was used the microwave of 2.45 GHz to reduce the construction cost of the source as much as possible. This ion source could not obtain enough intensity of C2+ because there were problems in microwave injection and beam extraction system. The second and third ion sources, named Kei and Kei2, solved these problems. The structure of Kei and Kei2 were similar, however Kei2 improved on the magnetic field configuration. The beam intensity of 0.26 mA and 0.78 mA for C4+ were obtained by Kei and by Kei2, respectively. All of later C-ion RT facilities in Japan, the Gunma University Heavy Ion Medical Center, the Saga Heavy Ion Medical Accelerator in Tosu, and the Ion-beam Radiation Oncology Center in Kanagawa, installed copies of Kei2 and named them KeiGM, KeiSA, and KeiGM3. On the other hand, the original Kei2 have been installed in the HIMAC at NIRS and produces carbon beams for experimental use. Developments and some improvements of these Kei-series ECR ion sources will be reported.", "subitem_description_type": "Abstract"}]}, "item_10003_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "http://www.rarf.riken.jp/hiat2015/proceedings/html/inst.htm"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.rarf.riken.jp/hiat2015/proceedings/html/inst.htm", "subitem_relation_type_select": "URI"}}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Muramatsu, Masayuki"}], "nameIdentifiers": [{"nameIdentifier": "558025", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Anne, Drentje"}], "nameIdentifiers": [{"nameIdentifier": "558026", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kitagawa, Atsushi"}], "nameIdentifiers": [{"nameIdentifier": "558027", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村松 正幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "558028", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "アルネ ドレンチェ", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "558029", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北川 敦志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "558030", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "Development of Electron Cyclotron Resonance Ion Sources for Carbon-Ion Radiotherapy", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Development of Electron Cyclotron Resonance Ion Sources for Carbon-Ion Radiotherapy"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/54620", "pubdate": {"attribute_name": "公開日", "attribute_value": "2016-01-14"}, "publish_date": "2016-01-14", "publish_status": "0", "recid": "54620", "relation": {}, "relation_version_is_last": true, "title": ["Development of Electron Cyclotron Resonance Ion Sources for Carbon-Ion Radiotherapy"], "weko_shared_id": -1}
Development of Electron Cyclotron Resonance Ion Sources for Carbon-Ion Radiotherapy
https://repo.qst.go.jp/records/54620
https://repo.qst.go.jp/records/54620ab8abd1d-31c3-4b30-9f47-d8125dd0b488
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-01-14 | |||||
タイトル | ||||||
タイトル | Development of Electron Cyclotron Resonance Ion Sources for Carbon-Ion Radiotherapy | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Muramatsu, Masayuki
× Muramatsu, Masayuki× Anne, Drentje× Kitagawa, Atsushi× 村松 正幸× アルネ ドレンチェ× 北川 敦志 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Compact ECR ion sources have been developed for high energy carbon-ion radiotherapy (C-ion RT). Three compact ECR ion sources have been developed as the prototype at NIRS. The first ion source was used the microwave of 2.45 GHz to reduce the construction cost of the source as much as possible. This ion source could not obtain enough intensity of C2+ because there were problems in microwave injection and beam extraction system. The second and third ion sources, named Kei and Kei2, solved these problems. The structure of Kei and Kei2 were similar, however Kei2 improved on the magnetic field configuration. The beam intensity of 0.26 mA and 0.78 mA for C4+ were obtained by Kei and by Kei2, respectively. All of later C-ion RT facilities in Japan, the Gunma University Heavy Ion Medical Center, the Saga Heavy Ion Medical Accelerator in Tosu, and the Ion-beam Radiation Oncology Center in Kanagawa, installed copies of Kei2 and named them KeiGM, KeiSA, and KeiGM3. On the other hand, the original Kei2 have been installed in the HIMAC at NIRS and produces carbon beams for experimental use. Developments and some improvements of these Kei-series ECR ion sources will be reported. | |||||
書誌情報 |
HIAT2015 - Proceedings 発行日 2015-09 |
|||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.rarf.riken.jp/hiat2015/proceedings/html/inst.htm | |||||
関連名称 | http://www.rarf.riken.jp/hiat2015/proceedings/html/inst.htm |