WEKO3
アイテム
{"_buckets": {"deposit": "c3b503b6-3389-43bf-a92d-a4282c363f9f"}, "_deposit": {"created_by": 1, "id": "52992", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "52992"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00052992", "sets": ["2"]}, "author_link": ["540552", "540547", "540549", "540550", "540546", "540551", "540545", "540548"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2002-09", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "207", "bibliographicPageStart": "206", "bibliographic_titles": [{"bibliographic_title": "Proceedings of The Third Korea-Japan Joint Meeting on Medical Physics and The Second Asia Oceania Congress of Medical Physics"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The effective dose due to the X-Ray radiography in the patient positioning for the heavy ion radiotherapy was measured on three regions, chest, upper-abdomen and pelvis. All the radiographic systems and the conditions used in the measurements were same as the clinical trial being performed in National Institute of Radiological Sciences, Japan. The organ or tissue for measurements was selected by following ICRP60 and the effective dose was calculated from measured organ doses and the surface dose.", "subitem_description_type": "Abstract"}]}, "item_10003_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1589-6691", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Hirai, Masaaki"}], "nameIdentifiers": [{"nameIdentifier": "540545", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishizawa, Kanae"}], "nameIdentifiers": [{"nameIdentifier": "540546", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shibayama, Kouichi"}], "nameIdentifiers": [{"nameIdentifier": "540547", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanai, Tatsuaki"}], "nameIdentifiers": [{"nameIdentifier": "540548", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平井 正明", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "540549", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "西澤 かな枝", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "540550", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "柴山 晃一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "540551", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金井 達明", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "540552", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "Dose Estimation of Patient by X-ray Positioning in Particle Cancer Therapy", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Dose Estimation of Patient by X-ray Positioning in Particle Cancer Therapy"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/52992", "pubdate": {"attribute_name": "公開日", "attribute_value": "2003-01-29"}, "publish_date": "2003-01-29", "publish_status": "0", "recid": "52992", "relation": {}, "relation_version_is_last": true, "title": ["Dose Estimation of Patient by X-ray Positioning in Particle Cancer Therapy"], "weko_shared_id": -1}
Dose Estimation of Patient by X-ray Positioning in Particle Cancer Therapy
https://repo.qst.go.jp/records/52992
https://repo.qst.go.jp/records/52992cc8145f9-716b-4750-ba78-dd3ae1a3c6e0
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2003-01-29 | |||||
タイトル | ||||||
タイトル | Dose Estimation of Patient by X-ray Positioning in Particle Cancer Therapy | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Hirai, Masaaki
× Hirai, Masaaki× Nishizawa, Kanae× Shibayama, Kouichi× Kanai, Tatsuaki× 平井 正明× 西澤 かな枝× 柴山 晃一× 金井 達明 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The effective dose due to the X-Ray radiography in the patient positioning for the heavy ion radiotherapy was measured on three regions, chest, upper-abdomen and pelvis. All the radiographic systems and the conditions used in the measurements were same as the clinical trial being performed in National Institute of Radiological Sciences, Japan. The organ or tissue for measurements was selected by following ICRP60 and the effective dose was calculated from measured organ doses and the surface dose. | |||||
書誌情報 |
Proceedings of The Third Korea-Japan Joint Meeting on Medical Physics and The Second Asia Oceania Congress of Medical Physics p. 206-207, 発行日 2002-09 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1589-6691 |