{"created":"2023-05-15T14:38:31.320372+00:00","id":52992,"links":{},"metadata":{"_buckets":{"deposit":"c3b503b6-3389-43bf-a92d-a4282c363f9f"},"_deposit":{"created_by":1,"id":"52992","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"52992"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00052992","sets":["2"]},"author_link":["540552","540547","540549","540550","540546","540551","540545","540548"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2002-09","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"207","bibliographicPageStart":"206","bibliographic_titles":[{"bibliographic_title":"Proceedings of The Third Korea-Japan Joint Meeting on Medical Physics and The Second Asia Oceania Congress of Medical Physics"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The effective dose due to the X-Ray radiography in the patient positioning for the heavy ion radiotherapy was measured on three regions, chest, upper-abdomen and pelvis. All the radiographic systems and the conditions used in the measurements were same as the clinical trial being performed in National Institute of Radiological Sciences, Japan. The organ or tissue for measurements was selected by following ICRP60 and the effective dose was calculated from measured organ doses and the surface dose.","subitem_description_type":"Abstract"}]},"item_10003_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1589-6691","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hirai, Masaaki"}],"nameIdentifiers":[{"nameIdentifier":"540545","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nishizawa, Kanae"}],"nameIdentifiers":[{"nameIdentifier":"540546","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shibayama, Kouichi"}],"nameIdentifiers":[{"nameIdentifier":"540547","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanai, Tatsuaki"}],"nameIdentifiers":[{"nameIdentifier":"540548","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"平井 正明","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"540549","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"西澤 かな枝","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"540550","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"柴山 晃一","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"540551","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金井 達明","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"540552","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"Dose Estimation of Patient by X-ray Positioning in Particle Cancer Therapy","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Dose Estimation of Patient by X-ray Positioning in Particle Cancer Therapy"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2003-01-29"},"publish_date":"2003-01-29","publish_status":"0","recid":"52992","relation_version_is_last":true,"title":["Dose Estimation of Patient by X-ray Positioning in Particle Cancer Therapy"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:17:43.293629+00:00"}