ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

A rapid method for accurate determination of 241Am by sector field inductively coupled plasma mass spectrometry and its application to Sellafield site soil samples

https://repo.qst.go.jp/records/48586
https://repo.qst.go.jp/records/48586
7582fa2e-daeb-499d-995f-2c71843379f9
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-03-19
タイトル
タイトル A rapid method for accurate determination of 241Am by sector field inductively coupled plasma mass spectrometry and its application to Sellafield site soil samples
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Wang, Zhongtang

× Wang, Zhongtang

WEKO 488562

Wang, Zhongtang

Search repository
Zheng, Jian

× Zheng, Jian

WEKO 488563

Zheng, Jian

Search repository
Imanaka, Tetsuji

× Imanaka, Tetsuji

WEKO 488564

Imanaka, Tetsuji

Search repository
Uchida, Shigeo

× Uchida, Shigeo

WEKO 488565

Uchida, Shigeo

Search repository
鄭 建

× 鄭 建

WEKO 488566

en 鄭 建

Search repository
内田 滋夫

× 内田 滋夫

WEKO 488567

en 内田 滋夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 Americium is one of the toxic radionuclides that isreleased from nuclear weapon tests and nuclear industry activities. To quickly characterize the released Am for nuclear emergency response, a new method was developed by combining HNO3 leaching, co-precipitation, extraction chromatography and SF-ICP-MS measurement; specifically, CaF2 co-precipitation is used to remove major metals, extraction chromatography by UTEVA, DGA-N and TEVA resins is used to remove interfering elements (IEs) and rare earth elements (REEs), and an Apex-ICP-MS analytical system is used to determine Am isotopes. The method was evaluated with three standard reference materials (IAEA-soil-6, IAEA-384 and IAEA-385) and the results showed that 241Am activities were accurately determined, in a short analytical time (2 days), with a high decontamination factor for the IEs (e.g. DF (Pu) = 7.4 × 105), and a high chemical recovery (63-88%). This method was further applied to analyze soil samples collected around the Sellafield nuclear complex, and high241Am activities (5.24 – 1179 mBq/g) were observed.
書誌情報 Journal of Analytical Atomic Spectrometry

巻 32, p. 2034-2040, 発行日 2017-10
出版者
出版者 Royal Society of Chemistry, UK
DOI
識別子タイプ DOI
関連識別子 10.1039/C7JA00201G
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:26:30.835484
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3