{"created":"2023-05-15T14:37:39.793594+00:00","id":48586,"links":{},"metadata":{"_buckets":{"deposit":"fcc854bb-2cbe-4d46-94a4-76f17c16733e"},"_deposit":{"created_by":1,"id":"48586","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"48586"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00048586","sets":["1"]},"author_link":["488564","488565","488563","488566","488562","488567"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-10","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"2040","bibliographicPageStart":"2034","bibliographicVolumeNumber":"32","bibliographic_titles":[{"bibliographic_title":"Journal of Analytical Atomic Spectrometry"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Americium is one of the toxic radionuclides that isreleased from nuclear weapon tests and nuclear industry activities. To quickly characterize the released Am for nuclear emergency response, a new method was developed by combining HNO3 leaching, co-precipitation, extraction chromatography and SF-ICP-MS measurement; specifically, CaF2 co-precipitation is used to remove major metals, extraction chromatography by UTEVA, DGA-N and TEVA resins is used to remove interfering elements (IEs) and rare earth elements (REEs), and an Apex-ICP-MS analytical system is used to determine Am isotopes. The method was evaluated with three standard reference materials (IAEA-soil-6, IAEA-384 and IAEA-385) and the results showed that 241Am activities were accurately determined, in a short analytical time (2 days), with a high decontamination factor for the IEs (e.g. DF (Pu) = 7.4 × 105), and a high chemical recovery (63-88%). This method was further applied to analyze soil samples collected around the Sellafield nuclear complex, and high241Am activities (5.24 – 1179 mBq/g) were observed.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Royal Society of Chemistry, UK"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1039/C7JA00201G","subitem_relation_type_select":"DOI"}}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Wang, Zhongtang"}],"nameIdentifiers":[{"nameIdentifier":"488562","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Zheng, Jian"}],"nameIdentifiers":[{"nameIdentifier":"488563","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Imanaka, Tetsuji"}],"nameIdentifiers":[{"nameIdentifier":"488564","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Uchida, Shigeo"}],"nameIdentifiers":[{"nameIdentifier":"488565","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鄭 建","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"488566","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"内田 滋夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"488567","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"A rapid method for accurate determination of 241Am by sector field inductively coupled plasma mass spectrometry and its application to Sellafield site soil samples","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"A rapid method for accurate determination of 241Am by sector field inductively coupled plasma mass spectrometry and its application to Sellafield site soil samples"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-03-19"},"publish_date":"2018-03-19","publish_status":"0","recid":"48586","relation_version_is_last":true,"title":["A rapid method for accurate determination of 241Am by sector field inductively coupled plasma mass spectrometry and its application to Sellafield site soil samples"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:26:30.732301+00:00"}