WEKO3
アイテム
{"_buckets": {"deposit": "02825b4e-d5c9-4fc4-87f7-827d791b3def"}, "_deposit": {"created_by": 1, "id": "48351", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "48351"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00048351", "sets": ["1"]}, "author_link": ["485932", "485928", "485929", "485930", "485931", "485933"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2017-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "37", "bibliographicPageStart": "34", "bibliographicVolumeNumber": "37", "bibliographic_titles": [{"bibliographic_title": "医学物理"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A calibration method for CT-number to stopping-power-ratio conversion was recently proposed as a revision of the Japanese de facto standard method that has been used at particle-therapy centers in Japan for over a decade. The revised method deals with 11 representative tissues with specific elemental composition and density, based on a latest compilation of standard tissue data. We report here how the revision was actually implemented into clinical practice. We applied the revised method to 7 CT-scanning conditions currently in use for treatment planning. For each condition, we derived CT numbers and stopping-power ratios of the representative tissues to constitute a polyline conversion function. We analyzed the target-depth change by the revision for 38 beams in treatment plans for 13 randomly sampled patients. The revision caused a mean change of +0.3 mm with a standard deviation of 0.4 mm. The maximum change was +1.2 mm or +0.5% of the depth, which may be clinically insignificant. The transition to the revised method was straightforward and would slightly improve the accuracy of beam range in particle therapy.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本医学物理学会"}]}, "item_8_relation_13": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "28924096", "subitem_relation_type_select": "PMID"}}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.11323/jjmp.37.1_34", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "https://doi.org/10.11323/jjmp.37.1_34"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.11323/jjmp.37.1_34", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1345-5354", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "兼松, 伸幸"}], "nameIdentifiers": [{"nameIdentifier": "485928", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森, 慎一郎"}], "nameIdentifiers": [{"nameIdentifier": "485929", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "稲庭, 拓"}], "nameIdentifiers": [{"nameIdentifier": "485930", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "兼松 伸幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "485931", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "森 慎一郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "485932", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "稲庭 拓", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "485933", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "粒子線治療計画のためのCT値阻止能比変換の校正方法の更新", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "粒子線治療計画のためのCT値阻止能比変換の校正方法の更新"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/48351", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-06"}, "publish_date": "2017-10-06", "publish_status": "0", "recid": "48351", "relation": {}, "relation_version_is_last": true, "title": ["粒子線治療計画のためのCT値阻止能比変換の校正方法の更新"], "weko_shared_id": -1}
粒子線治療計画のためのCT値阻止能比変換の校正方法の更新
https://repo.qst.go.jp/records/48351
https://repo.qst.go.jp/records/4835168a4adc5-b066-4bd8-8fc7-1181281cd20e
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-06 | |||||
タイトル | ||||||
タイトル | 粒子線治療計画のためのCT値阻止能比変換の校正方法の更新 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
兼松, 伸幸
× 兼松, 伸幸× 森, 慎一郎× 稲庭, 拓× 兼松 伸幸× 森 慎一郎× 稲庭 拓 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A calibration method for CT-number to stopping-power-ratio conversion was recently proposed as a revision of the Japanese de facto standard method that has been used at particle-therapy centers in Japan for over a decade. The revised method deals with 11 representative tissues with specific elemental composition and density, based on a latest compilation of standard tissue data. We report here how the revision was actually implemented into clinical practice. We applied the revised method to 7 CT-scanning conditions currently in use for treatment planning. For each condition, we derived CT numbers and stopping-power ratios of the representative tissues to constitute a polyline conversion function. We analyzed the target-depth change by the revision for 38 beams in treatment plans for 13 randomly sampled patients. The revision caused a mean change of +0.3 mm with a standard deviation of 0.4 mm. The maximum change was +1.2 mm or +0.5% of the depth, which may be clinically insignificant. The transition to the revised method was straightforward and would slightly improve the accuracy of beam range in particle therapy. | |||||
書誌情報 |
医学物理 巻 37, 号 1, p. 34-37, 発行日 2017-09 |
|||||
出版者 | ||||||
出版者 | 日本医学物理学会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1345-5354 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 28924096 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.11323/jjmp.37.1_34 | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.11323/jjmp.37.1_34 | |||||
関連名称 | https://doi.org/10.11323/jjmp.37.1_34 |