WEKO3
アイテム
Respiration-gated fast-rescanning carbon-ion radiotherapy
https://repo.qst.go.jp/records/48094
https://repo.qst.go.jp/records/4809489c95e4c-f70b-46b6-b5ba-abda6528fae9
| Item type | 学術雑誌論文 / Journal Article(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2017-07-13 | |||||
| タイトル | ||||||
| タイトル | Respiration-gated fast-rescanning carbon-ion radiotherapy | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
| 資源タイプ | journal article | |||||
| アクセス権 | ||||||
| アクセス権 | metadata only access | |||||
| アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
| 著者 |
エブナー, ダニエル
× エブナー, ダニエル× 辻, 比呂志× 安田, 茂雄× 山本, 直敬× 森, 慎一郎× 鎌田, 正× エブナー ダニエル× 辻 比呂志× 安田 茂雄× 山本 直敬× 森 慎一郎× 鎌田 正 |
|||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | Phase-controlled rescanning of the carbon-ion beam offers fast and precise dose application with decreased irradiation of normal tissue. However, organ movement with respiration remains a unique challenge. Technological development has enabled the simultaneous application of beam- energy-modulated markerless phase-controlled rescanning with respiration gating, allowing scan- ning treatment of respiration-mobile tumors with carbon. A total of 10 patients with tumors in the liver or lung were treated in a feasibility study at our facility using this combination. At a median of 10.5 months, follow-up examination including computed tomography/magnetic resonance imaging revealed no grade 2+ acute adverse effects with this new therapy. Two patients with complex disease experienced local recurrence, which may be improved with increased dose deliv- ery. One patient died of unrelated causes. All other patients are alive with good control at the time of writing. Though long-term observation is pending, these are promising initial results for use of the carbon-beam phase-controlled rescanning method in respiration-mobile disease. | |||||
| 書誌情報 |
Japanese Journal of Clinical Oncology 巻 47, 号 1, p. 80-83, 発行日 2017-01 |
|||||
| 出版者 | ||||||
| 出版者 | OXFORD Academic | |||||
| ISSN | ||||||
| 収録物識別子タイプ | ISSN | |||||
| 収録物識別子 | 0368-2811 | |||||
| DOI | ||||||
| 識別子タイプ | DOI | |||||
| 関連識別子 | 10.1093/jjco/hyw144 | |||||
| 関連サイト | ||||||
| 識別子タイプ | URI | |||||
| 関連識別子 | https://academic.oup.com/jjco/article-abstract/47/1/80/2527617/Respiration-gated-fast-rescanning-carbon-ion?redirectedFrom=fulltext | |||||
| 関連名称 | https://academic.oup.com/jjco/article-abstract/47/1/80/2527617/Respiration-gated-fast-rescanning-carbon-ion?redirectedFrom=fulltext | |||||