{"created":"2023-05-15T14:37:17.981651+00:00","id":48094,"links":{},"metadata":{"_buckets":{"deposit":"68945742-a79d-4d8c-95fc-094a054d2183"},"_deposit":{"created_by":1,"id":"48094","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"48094"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00048094","sets":["1"]},"author_link":["482943","482937","482946","482945","482941","482936","482940","482935","482938","482942","482944","482939"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"83","bibliographicPageStart":"80","bibliographicVolumeNumber":"47","bibliographic_titles":[{"bibliographic_title":"Japanese Journal of Clinical Oncology"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Phase-controlled rescanning of the carbon-ion beam offers fast and precise dose application with decreased irradiation of normal tissue. However, organ movement with respiration remains a unique challenge. Technological development has enabled the simultaneous application of beam- energy-modulated markerless phase-controlled rescanning with respiration gating, allowing scan- ning treatment of respiration-mobile tumors with carbon. A total of 10 patients with tumors in the liver or lung were treated in a feasibility study at our facility using this combination. At a median of 10.5 months, follow-up examination including computed tomography/magnetic resonance imaging revealed no grade 2+ acute adverse effects with this new therapy. Two patients with complex disease experienced local recurrence, which may be improved with increased dose deliv- ery. One patient died of unrelated causes. All other patients are alive with good control at the time of writing. Though long-term observation is pending, these are promising initial results for use of the carbon-beam phase-controlled rescanning method in respiration-mobile disease.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"OXFORD Academic"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1093/jjco/hyw144","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"https://academic.oup.com/jjco/article-abstract/47/1/80/2527617/Respiration-gated-fast-rescanning-carbon-ion?redirectedFrom=fulltext"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://academic.oup.com/jjco/article-abstract/47/1/80/2527617/Respiration-gated-fast-rescanning-carbon-ion?redirectedFrom=fulltext","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0368-2811","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"エブナー, ダニエル"}],"nameIdentifiers":[{"nameIdentifier":"482935","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"辻, 比呂志"}],"nameIdentifiers":[{"nameIdentifier":"482936","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"安田, 茂雄"}],"nameIdentifiers":[{"nameIdentifier":"482937","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山本, 直敬"}],"nameIdentifiers":[{"nameIdentifier":"482938","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"森, 慎一郎"}],"nameIdentifiers":[{"nameIdentifier":"482939","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鎌田, 正"}],"nameIdentifiers":[{"nameIdentifier":"482940","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"エブナー ダニエル","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"482941","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"辻 比呂志","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"482942","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"安田 茂雄","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"482943","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山本 直敬","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"482944","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"森 慎一郎","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"482945","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鎌田 正","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"482946","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Respiration-gated fast-rescanning carbon-ion radiotherapy","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Respiration-gated fast-rescanning carbon-ion radiotherapy"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-07-13"},"publish_date":"2017-07-13","publish_status":"0","recid":"48094","relation_version_is_last":true,"title":["Respiration-gated fast-rescanning carbon-ion radiotherapy"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:32:02.961210+00:00"}