WEKO3
アイテム
{"_buckets": {"deposit": "34335b0f-dda3-4037-94cf-09faa27a9676"}, "_deposit": {"created_by": 1, "id": "47858", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47858"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047858", "sets": ["1"]}, "author_link": ["480479", "480478"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2016-06", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1/3", "bibliographicPageEnd": "243", "bibliographicPageStart": "238", "bibliographicVolumeNumber": "172", "bibliographic_titles": [{"bibliographic_title": "Radiation Protection Dosimetry"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The most popular and “gold standard” phenomenon in Biological dosimetryis the appearance of dicentric chromosomes in metaphase in white blood cells. The metaphase finder is a tool for biological dosimetry that finds metaphase cells on slide glasses. The author and a software company were using new special software that was faster than conventional systems. We used a Nikon Eclipse Ni-E microscope with motorized X-Y stage, 4x objective lens and 1920 x 1024 pixels color camera for hardware. The software uses mathematical morphology filters. The new system was compact and low-priced. And the remarkable point is, this system can be applicable not only human blood, but also non-human samples. The speed was 208 to 236 seconds per 5 x 20 mm area, while capturing 378 images, which achieved the aim of the project. The false positive ratio achieved below 5 % in some slides.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Oxford University Press."}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1093/rpd/ncw152", "subitem_relation_type_select": "DOI"}}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "古川, 章"}], "nameIdentifiers": [{"nameIdentifier": "480478", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古川 章", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "480479", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "The project of another low-cost metaphase finder", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "The project of another low-cost metaphase finder"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47858", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-04-27"}, "publish_date": "2017-04-27", "publish_status": "0", "recid": "47858", "relation": {}, "relation_version_is_last": true, "title": ["The project of another low-cost metaphase finder"], "weko_shared_id": -1}
The project of another low-cost metaphase finder
https://repo.qst.go.jp/records/47858
https://repo.qst.go.jp/records/478588b6867ca-048b-4df2-affe-6e5f974b463a
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-04-27 | |||||
タイトル | ||||||
タイトル | The project of another low-cost metaphase finder | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
古川, 章
× 古川, 章× 古川 章 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The most popular and “gold standard” phenomenon in Biological dosimetryis the appearance of dicentric chromosomes in metaphase in white blood cells. The metaphase finder is a tool for biological dosimetry that finds metaphase cells on slide glasses. The author and a software company were using new special software that was faster than conventional systems. We used a Nikon Eclipse Ni-E microscope with motorized X-Y stage, 4x objective lens and 1920 x 1024 pixels color camera for hardware. The software uses mathematical morphology filters. The new system was compact and low-priced. And the remarkable point is, this system can be applicable not only human blood, but also non-human samples. The speed was 208 to 236 seconds per 5 x 20 mm area, while capturing 378 images, which achieved the aim of the project. The false positive ratio achieved below 5 % in some slides. | |||||
書誌情報 |
Radiation Protection Dosimetry 巻 172, 号 1/3, p. 238-243, 発行日 2016-06 |
|||||
出版者 | ||||||
出版者 | Oxford University Press. | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1093/rpd/ncw152 |