{"created":"2023-05-15T14:37:07.755971+00:00","id":47858,"links":{},"metadata":{"_buckets":{"deposit":"34335b0f-dda3-4037-94cf-09faa27a9676"},"_deposit":{"created_by":1,"id":"47858","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"47858"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00047858","sets":["1"]},"author_link":["480479","480478"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1/3","bibliographicPageEnd":"243","bibliographicPageStart":"238","bibliographicVolumeNumber":"172","bibliographic_titles":[{"bibliographic_title":"Radiation Protection Dosimetry"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The most popular and “gold standard” phenomenon in Biological dosimetryis the appearance of dicentric chromosomes in metaphase in white blood cells. The metaphase finder is a tool for biological dosimetry that finds metaphase cells on slide glasses. The author and a software company were using new special software that was faster than conventional systems. We used a Nikon Eclipse Ni-E microscope with motorized X-Y stage, 4x objective lens and 1920 x 1024 pixels color camera for hardware. The software uses mathematical morphology filters. The new system was compact and low-priced. And the remarkable point is, this system can be applicable not only human blood, but also non-human samples. The speed was 208 to 236 seconds per 5 x 20 mm area, while capturing 378 images, which achieved the aim of the project. The false positive ratio achieved below 5 % in some slides.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Oxford University Press."}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1093/rpd/ncw152","subitem_relation_type_select":"DOI"}}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"古川, 章"}],"nameIdentifiers":[{"nameIdentifier":"480478","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"古川 章","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"480479","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"The project of another low-cost metaphase finder","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"The project of another low-cost metaphase finder"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-04-27"},"publish_date":"2017-04-27","publish_status":"0","recid":"47858","relation_version_is_last":true,"title":["The project of another low-cost metaphase finder"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:34:46.513225+00:00"}