{"_buckets": {"deposit": "0bcf6a90-7e74-4f8b-b8d0-9b7f38b9fedd"}, "_deposit": {"created_by": 1, "id": "47840", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47840"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047840", "sets": ["1"]}, "author_link": ["480231", "480232", "480233"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2017-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "220", "bibliographicPageStart": "214", "bibliographicVolumeNumber": "12", "bibliographic_titles": [{"bibliographic_title": "IEEJ Transactions on Electrical and Electronic Engineering"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A dc -1 MV insulating transformer has been developed for the power supply of the neutral beam injector (NBI) at ITER. A dc long pulse -1 MV insulation structure between the primary and secondary windings, considering potential variation in the insulator for dc long pulse, has been designed. Simultaneous development of a compound bushing which consists of an ac 500 kV condenser bushing inside a cylindrical fiber reinforced plastic (FRP) tube has been carried out. The dc -1 MV insulation design has been verified by high voltage insulation tests of ac 50 Hz 1300 kV peak for 1 minute; dc -1200 kV for one hour; and a long duration test of dc -1060 kV for 5 hours. These results showed that the insulating transformer satisfy the power supply requirements for the ITER NBI.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "WILEY"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1002/tee 22368", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1931-4973", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "渡邊, 和弘"}], "nameIdentifiers": [{"nameIdentifier": "480231", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山中晴彦、前島哲也、柏木美恵子、戸張博、井上多加志、花田磨砂也、田中滋、山口耕平、門脇慎"}], "nameIdentifiers": [{"nameIdentifier": "480232", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "渡邊 和弘", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "480233", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Development of a DC -1 MV Insulating Transformer for Neutral Beam Injectors", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Development of a DC -1 MV Insulating Transformer for Neutral Beam Injectors"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47840", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-04-27"}, "publish_date": "2017-04-27", "publish_status": "0", "recid": "47840", "relation": {}, "relation_version_is_last": true, "title": ["Development of a DC -1 MV Insulating Transformer for Neutral Beam Injectors"], "weko_shared_id": -1}
Development of a DC -1 MV Insulating Transformer for Neutral Beam Injectors
https://repo.qst.go.jp/records/47840
https://repo.qst.go.jp/records/47840842c3d4c-0554-4283-bd47-4f226532b626
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-04-27 | |||||
タイトル | ||||||
タイトル | Development of a DC -1 MV Insulating Transformer for Neutral Beam Injectors | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
渡邊, 和弘
× 渡邊, 和弘× 山中晴彦、前島哲也、柏木美恵子、戸張博、井上多加志、花田磨砂也、田中滋、山口耕平、門脇慎× 渡邊 和弘 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A dc -1 MV insulating transformer has been developed for the power supply of the neutral beam injector (NBI) at ITER. A dc long pulse -1 MV insulation structure between the primary and secondary windings, considering potential variation in the insulator for dc long pulse, has been designed. Simultaneous development of a compound bushing which consists of an ac 500 kV condenser bushing inside a cylindrical fiber reinforced plastic (FRP) tube has been carried out. The dc -1 MV insulation design has been verified by high voltage insulation tests of ac 50 Hz 1300 kV peak for 1 minute; dc -1200 kV for one hour; and a long duration test of dc -1060 kV for 5 hours. These results showed that the insulating transformer satisfy the power supply requirements for the ITER NBI. | |||||
書誌情報 |
IEEJ Transactions on Electrical and Electronic Engineering 巻 12, 号 2, p. 214-220, 発行日 2017-03 |
|||||
出版者 | ||||||
出版者 | WILEY | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1931-4973 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1002/tee 22368 |