{"created":"2023-05-15T14:37:06.973545+00:00","id":47840,"links":{},"metadata":{"_buckets":{"deposit":"0bcf6a90-7e74-4f8b-b8d0-9b7f38b9fedd"},"_deposit":{"created_by":1,"id":"47840","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"47840"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00047840","sets":["1"]},"author_link":["480231","480232","480233"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"220","bibliographicPageStart":"214","bibliographicVolumeNumber":"12","bibliographic_titles":[{"bibliographic_title":"IEEJ Transactions on Electrical and Electronic Engineering"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A dc -1 MV insulating transformer has been developed for the power supply of the neutral beam injector (NBI) at ITER. A dc long pulse -1 MV insulation structure between the primary and secondary windings, considering potential variation in the insulator for dc long pulse, has been designed. Simultaneous development of a compound bushing which consists of an ac 500 kV condenser bushing inside a cylindrical fiber reinforced plastic (FRP) tube has been carried out. The dc -1 MV insulation design has been verified by high voltage insulation tests of ac 50 Hz 1300 kV peak for 1 minute; dc -1200 kV for one hour; and a long duration test of dc -1060 kV for 5 hours. These results showed that the insulating transformer satisfy the power supply requirements for the ITER NBI.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"WILEY"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1002/tee 22368","subitem_relation_type_select":"DOI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1931-4973","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"渡邊, 和弘"}],"nameIdentifiers":[{"nameIdentifier":"480231","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山中晴彦、前島哲也、柏木美恵子、戸張博、井上多加志、花田磨砂也、田中滋、山口耕平、門脇慎"}],"nameIdentifiers":[{"nameIdentifier":"480232","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"渡邊 和弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"480233","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Development of a DC -1 MV Insulating Transformer for Neutral Beam Injectors","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Development of a DC -1 MV Insulating Transformer for Neutral Beam Injectors"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-04-27"},"publish_date":"2017-04-27","publish_status":"0","recid":"47840","relation_version_is_last":true,"title":["Development of a DC -1 MV Insulating Transformer for Neutral Beam Injectors"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:34:57.194925+00:00"}