{"_buckets": {"deposit": "de8aa40c-e804-41d9-b7dd-2027beca576c"}, "_deposit": {"created_by": 1, "id": "47448", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47448"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047448", "sets": ["1"]}, "author_link": ["475314", "475319", "475316", "475313", "475317", "475318", "475315"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2015-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "121", "bibliographicPageStart": "113", "bibliographicVolumeNumber": "33", "bibliographic_titles": [{"bibliographic_title": "Japanese Journal of Radiology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "PURPOSE:\nTo evaluate the feasibility of the iterative reconstruction (IR) method with low-dose multi-detector computed tomography (MDCT) for lung cancer screening.\nMATERIALS AND METHODS:\nA chest CT phantom containing simulated ground-glass nodules (GGNs) of 5 different sizes was scanned by use of 16-row and 64-row MDCT. Tube currents of 10, 20, and 30 mA were used for the low-dose CT. To assess the detectability of pure GGNs, a radiologist-performance test was conducted. Mean visual scores for simulated GGNs were compared for reconstructed images from filtered back-projection (FBP) and the IR method.\nRESULTS:\nWhen 64-row MDCT was used, visual scores for simulated GGNs were significantly higher for the IR method than for the FBP method under any conditions; scores were also significantly higher for 16-row MDCT under some conditions.\nCONCLUSIONS:\nThe results of this experimental chest phantom study showed that use of the IR method improved the detectability of simulated pure GGNs.", "subitem_description_type": "Abstract"}]}, "item_8_relation_13": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "25552203", "subitem_relation_type_select": "PMID"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1867-1071", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Akashita, Shiho"}], "nameIdentifiers": [{"nameIdentifier": "475313", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tachibana, Yasuhiko"}], "nameIdentifiers": [{"nameIdentifier": "475314", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakamaki, Kentaro"}], "nameIdentifiers": [{"nameIdentifier": "475315", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sogawa, Keiji"}], "nameIdentifiers": [{"nameIdentifier": "475316", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Inoue, Tomio"}], "nameIdentifiers": [{"nameIdentifier": "475317", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "立花 泰彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "475318", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "井上 登美夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "475319", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Detection of pure ground-glass nodules in the lung by low-dose multi-detector computed tomography, with use of an iterative reconstruction method: a comparison with conventional image reconstruction by the filtered back-projection method.", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Detection of pure ground-glass nodules in the lung by low-dose multi-detector computed tomography, with use of an iterative reconstruction method: a comparison with conventional image reconstruction by the filtered back-projection method."}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47448", "pubdate": {"attribute_name": "公開日", "attribute_value": "2016-08-10"}, "publish_date": "2016-08-10", "publish_status": "0", "recid": "47448", "relation": {}, "relation_version_is_last": true, "title": ["Detection of pure ground-glass nodules in the lung by low-dose multi-detector computed tomography, with use of an iterative reconstruction method: a comparison with conventional image reconstruction by the filtered back-projection method."], "weko_shared_id": -1}
Detection of pure ground-glass nodules in the lung by low-dose multi-detector computed tomography, with use of an iterative reconstruction method: a comparison with conventional image reconstruction by the filtered back-projection method.
https://repo.qst.go.jp/records/47448
https://repo.qst.go.jp/records/4744811bc388e-8d01-4146-98dc-32e22d5c50c1
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-08-10 | |||||
タイトル | ||||||
タイトル | Detection of pure ground-glass nodules in the lung by low-dose multi-detector computed tomography, with use of an iterative reconstruction method: a comparison with conventional image reconstruction by the filtered back-projection method. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Akashita, Shiho
× Akashita, Shiho× Tachibana, Yasuhiko× Sakamaki, Kentaro× Sogawa, Keiji× Inoue, Tomio× 立花 泰彦× 井上 登美夫 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | PURPOSE: To evaluate the feasibility of the iterative reconstruction (IR) method with low-dose multi-detector computed tomography (MDCT) for lung cancer screening. MATERIALS AND METHODS: A chest CT phantom containing simulated ground-glass nodules (GGNs) of 5 different sizes was scanned by use of 16-row and 64-row MDCT. Tube currents of 10, 20, and 30 mA were used for the low-dose CT. To assess the detectability of pure GGNs, a radiologist-performance test was conducted. Mean visual scores for simulated GGNs were compared for reconstructed images from filtered back-projection (FBP) and the IR method. RESULTS: When 64-row MDCT was used, visual scores for simulated GGNs were significantly higher for the IR method than for the FBP method under any conditions; scores were also significantly higher for 16-row MDCT under some conditions. CONCLUSIONS: The results of this experimental chest phantom study showed that use of the IR method improved the detectability of simulated pure GGNs. |
|||||
書誌情報 |
Japanese Journal of Radiology 巻 33, 号 3, p. 113-121, 発行日 2015-03 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1867-1071 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 25552203 |