WEKO3
アイテム
{"_buckets": {"deposit": "9a175360-8c0f-470d-9397-f614fb700d24"}, "_deposit": {"created_by": 1, "id": "47183", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47183"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047183", "sets": ["1"]}, "author_link": ["471526", "471533", "471532", "471521", "471523", "471524", "471530", "471531", "471522", "471529", "471520", "471525", "471527", "471528"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2015-02", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "511", "bibliographicPageStart": "504", "bibliographicVolumeNumber": "62", "bibliographic_titles": [{"bibliographic_title": "IEEE Transactions on Nuclear Science"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Microdosimetry is an extremely useful technique, used for dosimetry in unknown mixed radiation fields typical of space and aviation, as well as in hadron therapy. A new silicon microdosimeter with 3D sensitive volumes has been proposed to overcome the shortcomings of the conventional Tissue Equivalent Proportional Counter. In this article, the charge collection characteristics of a new 3D mesa microdosimeter were investigated using the ANSTO heavy ion microprobe utilizing 5.5 MeV ${rm He}^{2 +}$ and 2 MeV ${rm H}^ {+}$ ions. Measurement of the microdosimetric characteristics allowed for the determination of the Relative Biological Effectiveness of the $^{12}{rm C}$ heavy ion therapy beam at the Heavy Ion Medical Accelerator in Chiba (HIMAC), Japan. Well-defined sensitive volumes of the 3D mesa microdosimeter have been observed and the microdosimetric RBE obtained showed good agreement with the TEPC. The new 3D mesa “bridge” microdosimeter is a step forward towards a microdosimeter with fully free-standing 3D sensitive volumes.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IEEE"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://dx.doi.org/10.1109/TNS.2015.2391102", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0018-9499", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "T., Tran"}], "nameIdentifiers": [{"nameIdentifier": "471520", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Linh"}], "nameIdentifiers": [{"nameIdentifier": "471521", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Chartier, Lachlan"}], "nameIdentifiers": [{"nameIdentifier": "471522", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Prokopovich, Anthony"}], "nameIdentifiers": [{"nameIdentifier": "471523", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Petasecca, Marco"}], "nameIdentifiers": [{"nameIdentifier": "471524", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsufuji, Narihiro"}], "nameIdentifiers": [{"nameIdentifier": "471525", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Anatoly, Rozenfeld"}], "nameIdentifiers": [{"nameIdentifier": "471526", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "al., et"}], "nameIdentifiers": [{"nameIdentifier": "471527", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tran Thuy Linh", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "471528", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Chartier Lachlan", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "471529", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Prokopovich Anthony", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "471530", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Petasecca Marco", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "471531", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松藤 成弘", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "471532", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Anatoly Rozenfeld", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "471533", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "3D-Mesa \"Bridge\" Silicon Microdosimeter: Charge Collection Study and application to RBE Studies in 12C Radiation Therapy", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "3D-Mesa \"Bridge\" Silicon Microdosimeter: Charge Collection Study and application to RBE Studies in 12C Radiation Therapy"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47183", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-07-23"}, "publish_date": "2015-07-23", "publish_status": "0", "recid": "47183", "relation": {}, "relation_version_is_last": true, "title": ["3D-Mesa \"Bridge\" Silicon Microdosimeter: Charge Collection Study and application to RBE Studies in 12C Radiation Therapy"], "weko_shared_id": -1}
3D-Mesa "Bridge" Silicon Microdosimeter: Charge Collection Study and application to RBE Studies in 12C Radiation Therapy
https://repo.qst.go.jp/records/47183
https://repo.qst.go.jp/records/47183dc2aca2d-08aa-4b90-821c-e40e793d06ab
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-07-23 | |||||
タイトル | ||||||
タイトル | 3D-Mesa "Bridge" Silicon Microdosimeter: Charge Collection Study and application to RBE Studies in 12C Radiation Therapy | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
T., Tran
× T., Tran× Linh× Chartier, Lachlan× Prokopovich, Anthony× Petasecca, Marco× Matsufuji, Narihiro× Anatoly, Rozenfeld× al., et× Tran Thuy Linh× Chartier Lachlan× Prokopovich Anthony× Petasecca Marco× 松藤 成弘× Anatoly Rozenfeld |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Microdosimetry is an extremely useful technique, used for dosimetry in unknown mixed radiation fields typical of space and aviation, as well as in hadron therapy. A new silicon microdosimeter with 3D sensitive volumes has been proposed to overcome the shortcomings of the conventional Tissue Equivalent Proportional Counter. In this article, the charge collection characteristics of a new 3D mesa microdosimeter were investigated using the ANSTO heavy ion microprobe utilizing 5.5 MeV ${rm He}^{2 +}$ and 2 MeV ${rm H}^ {+}$ ions. Measurement of the microdosimetric characteristics allowed for the determination of the Relative Biological Effectiveness of the $^{12}{rm C}$ heavy ion therapy beam at the Heavy Ion Medical Accelerator in Chiba (HIMAC), Japan. Well-defined sensitive volumes of the 3D mesa microdosimeter have been observed and the microdosimetric RBE obtained showed good agreement with the TEPC. The new 3D mesa “bridge” microdosimeter is a step forward towards a microdosimeter with fully free-standing 3D sensitive volumes. | |||||
書誌情報 |
IEEE Transactions on Nuclear Science 巻 62, 号 2, p. 504-511, 発行日 2015-02 |
|||||
出版者 | ||||||
出版者 | IEEE | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0018-9499 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | http://dx.doi.org/10.1109/TNS.2015.2391102 |