{"created":"2023-05-15T14:36:37.841500+00:00","id":47183,"links":{},"metadata":{"_buckets":{"deposit":"9a175360-8c0f-470d-9397-f614fb700d24"},"_deposit":{"created_by":1,"id":"47183","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"47183"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00047183","sets":["1"]},"author_link":["471526","471533","471532","471521","471523","471524","471530","471531","471522","471529","471520","471525","471527","471528"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2015-02","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"511","bibliographicPageStart":"504","bibliographicVolumeNumber":"62","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Nuclear Science"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Microdosimetry is an extremely useful technique, used for dosimetry in unknown mixed radiation fields typical of space and aviation, as well as in hadron therapy. A new silicon microdosimeter with 3D sensitive volumes has been proposed to overcome the shortcomings of the conventional Tissue Equivalent Proportional Counter. In this article, the charge collection characteristics of a new 3D mesa microdosimeter were investigated using the ANSTO heavy ion microprobe utilizing 5.5 MeV ${rm He}^{2 +}$ and 2 MeV ${rm H}^ {+}$ ions. Measurement of the microdosimetric characteristics allowed for the determination of the Relative Biological Effectiveness of the $^{12}{rm C}$ heavy ion therapy beam at the Heavy Ion Medical Accelerator in Chiba (HIMAC), Japan. Well-defined sensitive volumes of the 3D mesa microdosimeter have been observed and the microdosimetric RBE obtained showed good agreement with the TEPC. The new 3D mesa “bridge” microdosimeter is a step forward towards a microdosimeter with fully free-standing 3D sensitive volumes.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://dx.doi.org/10.1109/TNS.2015.2391102","subitem_relation_type_select":"DOI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0018-9499","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"T., Tran"}],"nameIdentifiers":[{"nameIdentifier":"471520","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Linh"}],"nameIdentifiers":[{"nameIdentifier":"471521","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Chartier, Lachlan"}],"nameIdentifiers":[{"nameIdentifier":"471522","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Prokopovich, Anthony"}],"nameIdentifiers":[{"nameIdentifier":"471523","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Petasecca, Marco"}],"nameIdentifiers":[{"nameIdentifier":"471524","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Matsufuji, Narihiro"}],"nameIdentifiers":[{"nameIdentifier":"471525","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Anatoly, Rozenfeld"}],"nameIdentifiers":[{"nameIdentifier":"471526","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"al., et"}],"nameIdentifiers":[{"nameIdentifier":"471527","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tran Thuy Linh","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"471528","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Chartier Lachlan","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"471529","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Prokopovich Anthony","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"471530","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Petasecca Marco","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"471531","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松藤 成弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"471532","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Anatoly Rozenfeld","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"471533","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"3D-Mesa \"Bridge\" Silicon Microdosimeter: Charge Collection Study and application to RBE Studies in 12C Radiation Therapy","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"3D-Mesa \"Bridge\" Silicon Microdosimeter: Charge Collection Study and application to RBE Studies in 12C Radiation Therapy"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-07-23"},"publish_date":"2015-07-23","publish_status":"0","recid":"47183","relation_version_is_last":true,"title":["3D-Mesa \"Bridge\" Silicon Microdosimeter: Charge Collection Study and application to RBE Studies in 12C Radiation Therapy"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:42:56.555830+00:00"}