ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Resonance coupling induced enhancement of indirect transverse cooling in a laser-cooled ion beam

https://repo.qst.go.jp/records/46609
https://repo.qst.go.jp/records/46609
f9709239-d332-4430-bed3-22a72348e23e
Item type 学術雑誌論文 / Journal Article(1)
公開日 2013-10-17
タイトル
タイトル Resonance coupling induced enhancement of indirect transverse cooling in a laser-cooled ion beam
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nakao, Masao

× Nakao, Masao

WEKO 464630

Nakao, Masao

Search repository
Souda, Hikaru

× Souda, Hikaru

WEKO 464631

Souda, Hikaru

Search repository
Tanabe, Mikio

× Tanabe, Mikio

WEKO 464632

Tanabe, Mikio

Search repository
Tongu, Hiromu

× Tongu, Hiromu

WEKO 464633

Tongu, Hiromu

Search repository
Noda, Akira

× Noda, Akira

WEKO 464634

Noda, Akira

Search repository
Shirai, Toshiyuki

× Shirai, Toshiyuki

WEKO 464635

Shirai, Toshiyuki

Search repository
Grieser, Manfred

× Grieser, Manfred

WEKO 464636

Grieser, Manfred

Search repository
Okamoto, Hiromi

× Okamoto, Hiromi

WEKO 464637

Okamoto, Hiromi

Search repository
Smirnov, Alexander

× Smirnov, Alexander

WEKO 464638

Smirnov, Alexander

Search repository
et.al

× et.al

WEKO 464639

et.al

Search repository
田辺 幹夫

× 田辺 幹夫

WEKO 464640

en 田辺 幹夫

Search repository
頓宮 拓

× 頓宮 拓

WEKO 464641

en 頓宮 拓

Search repository
野田 章

× 野田 章

WEKO 464642

en 野田 章

Search repository
白井 敏之

× 白井 敏之

WEKO 464643

en 白井 敏之

Search repository
岡本 宏己

× 岡本 宏己

WEKO 464644

en 岡本 宏己

Search repository
抄録
内容記述タイプ Abstract
内容記述 We report the first observation of indirect resonantly enhanced transverse laser cooling of a bunched, stored ion beam of 40 keV 24Mg+. The longitudinal velocity distribution and the horizontal beam size of the laser-cooled 24Mg+ ion beam with 280 nm laser light were simultaneously observed by the use of standard fluorescence-based techniques. Keeping the operation point at (2.068, 1.105), the synchrotron tune (Vs) was changed from 0.0376 to 0.1299. A strong decrease in the cooled horizontal beam size and a corresponding increase in the equilibrium cooled momentum spread were observed at the expected synchrobetatron resonance coupling condition of Vs=0.068, which is the first observation of a resonantly induced coupling for enhanced indirect transverse laser cooling of an ion beam, and is an important step towards creating a crystalline ground state of the beam.
書誌情報 Physical Review Special Topics : Accelerator and Beams (Online Only URL:http://prst-ab.aps.org/)

巻 15, 号 11, p. 110102, 発行日 2012-11
ISSN
収録物識別子タイプ ISSN
収録物識別子 1098-4402
関連サイト
識別子タイプ URI
関連識別子 http://link.aps.org/doi/10.1103/PhysRevSTAB.15.110102
関連名称 http://link.aps.org/doi/10.1103/PhysRevSTAB.15.110102
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:49:44.275508
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3