@article{oai:repo.qst.go.jp:00046609, author = {Nakao, Masao and Souda, Hikaru and Tanabe, Mikio and Tongu, Hiromu and Noda, Akira and Shirai, Toshiyuki and Grieser, Manfred and Okamoto, Hiromi and Smirnov, Alexander and et.al and 田辺 幹夫 and 頓宮 拓 and 野田 章 and 白井 敏之 and 岡本 宏己}, issue = {11}, journal = {Physical Review Special Topics : Accelerator and Beams (Online Only URL:http://prst-ab.aps.org/)}, month = {Nov}, note = {We report the first observation of indirect resonantly enhanced transverse laser cooling of a bunched, stored ion beam of 40 keV 24Mg+. The longitudinal velocity distribution and the horizontal beam size of the laser-cooled 24Mg+ ion beam with 280 nm laser light were simultaneously observed by the use of standard fluorescence-based techniques. Keeping the operation point at (2.068, 1.105), the synchrotron tune (Vs) was changed from 0.0376 to 0.1299. A strong decrease in the cooled horizontal beam size and a corresponding increase in the equilibrium cooled momentum spread were observed at the expected synchrobetatron resonance coupling condition of Vs=0.068, which is the first observation of a resonantly induced coupling for enhanced indirect transverse laser cooling of an ion beam, and is an important step towards creating a crystalline ground state of the beam.}, title = {Resonance coupling induced enhancement of indirect transverse cooling in a laser-cooled ion beam}, volume = {15}, year = {2012} }