WEKO3
アイテム
Radiosensitivity of pimonidazole-unlabeled intratumor quiescent cell population to gamma-rays, accelerated carbon ion beams and boron neutron capture reaction
https://repo.qst.go.jp/records/46598
https://repo.qst.go.jp/records/46598360987cd-9a3a-4b2f-ac5a-4992a7225407
| Item type | 学術雑誌論文 / Journal Article(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2013-09-27 | |||||
| タイトル | ||||||
| タイトル | Radiosensitivity of pimonidazole-unlabeled intratumor quiescent cell population to gamma-rays, accelerated carbon ion beams and boron neutron capture reaction | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
| 資源タイプ | journal article | |||||
| アクセス権 | ||||||
| アクセス権 | metadata only access | |||||
| アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
| 著者 |
Masunaga, Shinichiro
× Masunaga, Shinichiro× Sakurai, Yoshinori× Tanaka, Hiroki× Hirayama, Ryoichi× Matsumoto, Yoshitaka× Uzawa, Akiko× Suzuki, Minoru× Kondo, Natsuko× Maruhashi, Akira× Ono, Koji× 平山 亮一× 松本 孔貴× 鵜澤 玲子× 丸橋 晃× 小野 公二 |
|||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | Objective: To detect the radiosensitivity of intratumour quiescent (Q) cells unlabelled with pimonidazole to accelerated carbon ion beams and the boron neutron capture reaction (BNCR). Methods: EL4 tumour-bearing C57BL/J mice received 5-bromo-29-deoxyuridine (BrdU) continuously to label all intratumour proliferating (P) cells. After the administration of pimonidazole, tumours were irradiated with c-rays, accelerated carbon ion beams or reactor neutron beams with the prior administration of a 10B-carrier. Responses of intratumour Q and total (P+Q) cell populations were assessed based on frequencies of micronucleation and apoptosis using immunofluorescence staining for BrdU. The response of pimonidazole-unlabelled tumour cells was assessed by means of apoptosis frequency using immunofluorescence staining for pimonidazole. Results: Following c-ray irradiation, the pimonidazole-unlabelled tumour cell fraction showed significantly enhanced radiosensitivity compared with the whole tumour cell fraction, more remarkably in the Q than total cell populations. However, a significantly greater decrease in radiosensitivity in the pimonidazole-unlabelled cell fraction, evaluated using a delayed assay or a decrease in radiation dose rate, was more clearly observed among the Q than total cells. These changes in radiosensitivity were suppressed following carbon ion beam and neutron beam-only irradiaton. In the BNCR, the use of a 10B-carrier, especially L-para-boronophenylalanine-10B, enhanced the sensitivity of the pimonidazole-unlabelled cells more clearly in the Q than total cells. Conclusion: The radiosensitivity of the pimonidazole-unlabelled cell fraction depends on the quality of radiation delivered and characteristics of the 10B-carrier used in the BNCR. |
|||||
| 書誌情報 |
British Journal of Radiology 巻 86, 号 1021, p. 20120302, 発行日 2013-03 |
|||||
| ISSN | ||||||
| 収録物識別子タイプ | ISSN | |||||
| 収録物識別子 | 0007-1285 | |||||
| DOI | ||||||
| 識別子タイプ | DOI | |||||
| 関連識別子 | 10.1259/bjr.20120302 | |||||