{"_buckets": {"deposit": "bb229c5d-7f3f-447a-9832-ae40dc7948ea"}, "_deposit": {"created_by": 1, "id": "46469", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "46469"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00046469", "sets": ["1"]}, "author_link": ["463011", "463018", "463016", "463014", "463012", "463015", "463019", "463013", "463017"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "26", "bibliographicPageStart": "17", "bibliographicVolumeNumber": "11", "bibliographic_titles": [{"bibliographic_title": "Magnetic Resonance in Medical Sciences"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "PURPOSE: In magnetic resonance imaging of the brain, BLADE is used to compensate for head motion. The technique focuses mainly on acquisition of T(2)-weighted or contrast-enhanced T(1)-weighted images in adults; its utility for nonenhanced T(1)-weighted imaging in children is not well established. We compared the quality of T(1)-weighted fluid-attenuated inversion recovery brain imaging with BLADE (T(1)-FLAIR-BLADE) to that of conventional spin-echo T(1)-weighted imaging (T(1)-SE) in pediatric patients who cannot stay still during MR imaging.\n\\nMATERIALS AND METHODS: Our investigation included a volunteer study and a retrospective clinical study. Six healthy adult volunteers underwent scanning to compare the contrast of T(1)-SE, T(1)-weighted fluid-attenuated inversion recovery imaging (T(1)-FLAIR), and T(1)-FLAIR-BLADE at both 1.5 and 3 tesla. Comparison was based on scores assigned independently by 2 blinded observers and by calculated contrast-to-noise ratio. The clinical study included 20 children who underwent both T(1)-SE and T(1)-FLAIR-BLADE at either 1.5 (n = 9) or 3 T (n = 11). On each sequence, 2 blinded observers independently scored visualization of the cerebral gyri and contrast between gray and white matter. We compared scores between sequences separately for 1.5 and 3T using Wilcoxon signed-rank tests.\n\\nRESULTS: At both 1.5 and 3T, contrast was better using T(1)-FLAIR and T(1)-FLAIR-BLADE than T(1)-SE in volunteers, and overall scores were significantly higher with T(1)-FLAIR-BLADE (P \u003c 0.05) than T(1)-SE in the clinical study.\n\\nCONCLUSION: T(1)-FLAIR-BLADE may be superior to T(1)-SE in demonstrating brain structures in children who cannot stay still and may be used to supplement or replace T(1)-SE when T(1)-SE is insufficient for patient motion.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1347-3182", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Tachibana, Yasuhiko"}], "nameIdentifiers": [{"nameIdentifier": "463011", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Niwa, Tetsu"}], "nameIdentifiers": [{"nameIdentifier": "463012", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kusagiri, Kouki"}], "nameIdentifiers": [{"nameIdentifier": "463013", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Aida, Noriko"}], "nameIdentifiers": [{"nameIdentifier": "463014", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "463015", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "立花 泰彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "463016", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "丹羽 徹", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "463017", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "草切 孝貴", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "463018", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "相田 典子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "463019", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Effective Performance of T1-weighted FLAIR Imaging with BLADE in Pediatric Brains", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Effective Performance of T1-weighted FLAIR Imaging with BLADE in Pediatric Brains"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/46469", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-12-21"}, "publish_date": "2012-12-21", "publish_status": "0", "recid": "46469", "relation": {}, "relation_version_is_last": true, "title": ["Effective Performance of T1-weighted FLAIR Imaging with BLADE in Pediatric Brains"], "weko_shared_id": -1}
Effective Performance of T1-weighted FLAIR Imaging with BLADE in Pediatric Brains
https://repo.qst.go.jp/records/46469
https://repo.qst.go.jp/records/464690a2606a8-f881-4e6c-9716-5f70870fbe11
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-12-21 | |||||
タイトル | ||||||
タイトル | Effective Performance of T1-weighted FLAIR Imaging with BLADE in Pediatric Brains | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Tachibana, Yasuhiko
× Tachibana, Yasuhiko× Niwa, Tetsu× Kusagiri, Kouki× Aida, Noriko× et.al× 立花 泰彦× 丹羽 徹× 草切 孝貴× 相田 典子 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | PURPOSE: In magnetic resonance imaging of the brain, BLADE is used to compensate for head motion. The technique focuses mainly on acquisition of T(2)-weighted or contrast-enhanced T(1)-weighted images in adults; its utility for nonenhanced T(1)-weighted imaging in children is not well established. We compared the quality of T(1)-weighted fluid-attenuated inversion recovery brain imaging with BLADE (T(1)-FLAIR-BLADE) to that of conventional spin-echo T(1)-weighted imaging (T(1)-SE) in pediatric patients who cannot stay still during MR imaging. \nMATERIALS AND METHODS: Our investigation included a volunteer study and a retrospective clinical study. Six healthy adult volunteers underwent scanning to compare the contrast of T(1)-SE, T(1)-weighted fluid-attenuated inversion recovery imaging (T(1)-FLAIR), and T(1)-FLAIR-BLADE at both 1.5 and 3 tesla. Comparison was based on scores assigned independently by 2 blinded observers and by calculated contrast-to-noise ratio. The clinical study included 20 children who underwent both T(1)-SE and T(1)-FLAIR-BLADE at either 1.5 (n = 9) or 3 T (n = 11). On each sequence, 2 blinded observers independently scored visualization of the cerebral gyri and contrast between gray and white matter. We compared scores between sequences separately for 1.5 and 3T using Wilcoxon signed-rank tests. \nRESULTS: At both 1.5 and 3T, contrast was better using T(1)-FLAIR and T(1)-FLAIR-BLADE than T(1)-SE in volunteers, and overall scores were significantly higher with T(1)-FLAIR-BLADE (P < 0.05) than T(1)-SE in the clinical study. \nCONCLUSION: T(1)-FLAIR-BLADE may be superior to T(1)-SE in demonstrating brain structures in children who cannot stay still and may be used to supplement or replace T(1)-SE when T(1)-SE is insufficient for patient motion. |
|||||
書誌情報 |
Magnetic Resonance in Medical Sciences 巻 11, 号 1, p. 17-26, 発行日 2012 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1347-3182 |