WEKO3
アイテム
{"_buckets": {"deposit": "253d48ab-979b-4fc1-b7b9-886fae03e36c"}, "_deposit": {"created_by": 1, "id": "45761", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "45761"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00045761", "sets": ["1"]}, "author_link": ["454889", "454884", "454885", "454880", "454882", "454881", "454877", "454883", "454887", "454888", "454876", "454878", "454886", "454879"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2010-02", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "57", "bibliographicPageStart": "53", "bibliographicVolumeNumber": "53", "bibliographic_titles": [{"bibliographic_title": "Journal of Labelled Compounds \u0026 Radiopharmaceuticals"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Recent studies revealed that thalidomide (1) has unique and broad pharmacological effects on multi-targets although the\napplication of 1 in therapy is still controversial. In this study, we synthesized nitrogen-13-labeled thalidomide ([13N]1) as a\npotential positron emission tomography (PET) probe using no-carrier-added [13N]NH3 as a labeling agent. By use of an\nautomated system, [13N]1 was prepared by reacting N-phthaloylglutamic anhydride (2) with [13N]NH3, following by\ncyclization with carbonyldiimidazole in a radiochemical yield of 56712% (based on [11N]NH3, corrected for decay) and\nspecific activity of 49724 GBq/mmol at the end of synthesis (EOS). At EOS, 570\u0026#8211;780MBq (n=7) of [13N]1 was obtained at a\nbeam current of 15 mA after 15 min proton bombardment with a synthesis time of 14 min from the end of bombardment. Using a small animal PET scanner, preliminary biodistribution of [13N]1 in mice was examined", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0362-4803", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kumata, Katsushi"}], "nameIdentifiers": [{"nameIdentifier": "454876", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takei, Makoto"}], "nameIdentifiers": [{"nameIdentifier": "454877", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yui, Jyouji"}], "nameIdentifiers": [{"nameIdentifier": "454878", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ogawa, Masanao"}], "nameIdentifiers": [{"nameIdentifier": "454879", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hatori, Akiko"}], "nameIdentifiers": [{"nameIdentifier": "454880", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Suzuki, Kazutoshi"}], "nameIdentifiers": [{"nameIdentifier": "454881", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Zhang, Ming-Rong"}], "nameIdentifiers": [{"nameIdentifier": "454882", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "熊田 勝志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "454883", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "武井 誠", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "454884", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "由井 譲二", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "454885", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小川 政直", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "454886", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "羽鳥 晶子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "454887", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木 和年", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "454888", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "張 明栄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "454889", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Radiosynthesis of 13N-labeled thalidomide using no-carrier-added [13N]NH3", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Radiosynthesis of 13N-labeled thalidomide using no-carrier-added [13N]NH3"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/45761", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-03-03"}, "publish_date": "2010-03-03", "publish_status": "0", "recid": "45761", "relation": {}, "relation_version_is_last": true, "title": ["Radiosynthesis of 13N-labeled thalidomide using no-carrier-added [13N]NH3"], "weko_shared_id": -1}
Radiosynthesis of 13N-labeled thalidomide using no-carrier-added [13N]NH3
https://repo.qst.go.jp/records/45761
https://repo.qst.go.jp/records/45761b07207aa-785d-4fd0-bb61-521150b6e3e1
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-03-03 | |||||
タイトル | ||||||
タイトル | Radiosynthesis of 13N-labeled thalidomide using no-carrier-added [13N]NH3 | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kumata, Katsushi
× Kumata, Katsushi× Takei, Makoto× Yui, Jyouji× Ogawa, Masanao× Hatori, Akiko× Suzuki, Kazutoshi× Zhang, Ming-Rong× 熊田 勝志× 武井 誠× 由井 譲二× 小川 政直× 羽鳥 晶子× 鈴木 和年× 張 明栄 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Recent studies revealed that thalidomide (1) has unique and broad pharmacological effects on multi-targets although the application of 1 in therapy is still controversial. In this study, we synthesized nitrogen-13-labeled thalidomide ([13N]1) as a potential positron emission tomography (PET) probe using no-carrier-added [13N]NH3 as a labeling agent. By use of an automated system, [13N]1 was prepared by reacting N-phthaloylglutamic anhydride (2) with [13N]NH3, following by cyclization with carbonyldiimidazole in a radiochemical yield of 56712% (based on [11N]NH3, corrected for decay) and specific activity of 49724 GBq/mmol at the end of synthesis (EOS). At EOS, 570–780MBq (n=7) of [13N]1 was obtained at a beam current of 15 mA after 15 min proton bombardment with a synthesis time of 14 min from the end of bombardment. Using a small animal PET scanner, preliminary biodistribution of [13N]1 in mice was examined |
|||||
書誌情報 |
Journal of Labelled Compounds & Radiopharmaceuticals 巻 53, 号 2, p. 53-57, 発行日 2010-02 |
|||||