{"_buckets": {"deposit": "0a5755cd-deac-480a-9b9a-2c464b1411ad"}, "_deposit": {"created_by": 1, "id": "45320", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "45320"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00045320", "sets": ["1"]}, "author_link": ["450231", "450234", "450228", "450230", "450233", "450236", "450232", "450229", "450235"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-08", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "7", "bibliographicPageEnd": "421", "bibliographicPageStart": "415", "bibliographicVolumeNumber": "26", "bibliographic_titles": [{"bibliographic_title": "Radiation Medicine"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Purpose: A comparative treatment planning study has been performed between carbon ion radiotherapy (CIRT) and photon radiotherapy [three-dimensional conformal radiotherapy (3D-CRT) and intensitymodulated radiotherapy (IMRT)] to assess the potential improvements and limitations that could result for locally advanced, nonresectable head and neck tumors.\nMaterials and methods: Seven patients, originally treated with CIRT, were randomly selected for the comparative study. The evaluations analyzed using dose-volume histogram parameters, conformity index, inhomogeneity coefficient, and dose to the organs at risk (OARs). \nResults: The mean conformity index was 1.46,1.43,and 1.22 for 3D-CRT, IMRT,and CIRT, respectively. The mean inhomogeneity coefficient was 0.05,0.07,and 0.02 for 3D-CRT, IMRT,and CIRT respectively. Photon plans resulted in greater volumes of normal tissues at 10% to 95% isodose levels compared with the corresponding carbon ion plans where the volumes increased by a factor of 1.2 to 2.7 for 3D-CRT and 1.2 to 2.0 for IMRT.\nConclusion: CIRT has the potential to improve the target dose conformity inhomogeneity coefficient, and OAR sparing when compared with 3D-CRT and IMRT. Compared with 3D-CRT, normal tissue exposure was reduced mainly in the mid-to low-isodose levels using IMRT. Additional improvement was obtained using CIRT.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0288-2043", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Islam, Amirul"}], "nameIdentifiers": [{"nameIdentifier": "450228", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yanagi, Takeshi"}], "nameIdentifiers": [{"nameIdentifier": "450229", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mizoe, Junetsu"}], "nameIdentifiers": [{"nameIdentifier": "450230", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mizuno, Hideyuki"}], "nameIdentifiers": [{"nameIdentifier": "450231", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsujii, Hirohiko"}], "nameIdentifiers": [{"nameIdentifier": "450232", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "柳 剛", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "450233", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "溝江 純悦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "450234", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "水野 秀之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "450235", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "辻井 博彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "450236", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Comparative study of dose distribution between carbon ion radiotherapy and photon radiotherapy for head and neck tumor", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Comparative study of dose distribution between carbon ion radiotherapy and photon radiotherapy for head and neck tumor"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/45320", "pubdate": {"attribute_name": "公開日", "attribute_value": "2008-11-18"}, "publish_date": "2008-11-18", "publish_status": "0", "recid": "45320", "relation": {}, "relation_version_is_last": true, "title": ["Comparative study of dose distribution between carbon ion radiotherapy and photon radiotherapy for head and neck tumor"], "weko_shared_id": -1}
Comparative study of dose distribution between carbon ion radiotherapy and photon radiotherapy for head and neck tumor
https://repo.qst.go.jp/records/45320
https://repo.qst.go.jp/records/4532008470549-f792-4843-b577-5471bea8f3cf
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-11-18 | |||||
タイトル | ||||||
タイトル | Comparative study of dose distribution between carbon ion radiotherapy and photon radiotherapy for head and neck tumor | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Islam, Amirul
× Islam, Amirul× Yanagi, Takeshi× Mizoe, Junetsu× Mizuno, Hideyuki× Tsujii, Hirohiko× 柳 剛× 溝江 純悦× 水野 秀之× 辻井 博彦 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: A comparative treatment planning study has been performed between carbon ion radiotherapy (CIRT) and photon radiotherapy [three-dimensional conformal radiotherapy (3D-CRT) and intensitymodulated radiotherapy (IMRT)] to assess the potential improvements and limitations that could result for locally advanced, nonresectable head and neck tumors. Materials and methods: Seven patients, originally treated with CIRT, were randomly selected for the comparative study. The evaluations analyzed using dose-volume histogram parameters, conformity index, inhomogeneity coefficient, and dose to the organs at risk (OARs). Results: The mean conformity index was 1.46,1.43,and 1.22 for 3D-CRT, IMRT,and CIRT, respectively. The mean inhomogeneity coefficient was 0.05,0.07,and 0.02 for 3D-CRT, IMRT,and CIRT respectively. Photon plans resulted in greater volumes of normal tissues at 10% to 95% isodose levels compared with the corresponding carbon ion plans where the volumes increased by a factor of 1.2 to 2.7 for 3D-CRT and 1.2 to 2.0 for IMRT. Conclusion: CIRT has the potential to improve the target dose conformity inhomogeneity coefficient, and OAR sparing when compared with 3D-CRT and IMRT. Compared with 3D-CRT, normal tissue exposure was reduced mainly in the mid-to low-isodose levels using IMRT. Additional improvement was obtained using CIRT. |
|||||
書誌情報 |
Radiation Medicine 巻 26, 号 7, p. 415-421, 発行日 2008-08 |
|||||