WEKO3
アイテム
{"_buckets": {"deposit": "40820002-536e-467b-8d9f-a5f7b31017f3"}, "_deposit": {"created_by": 1, "id": "44597", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44597"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044597", "sets": ["1"]}, "author_link": ["442890", "442892", "442894", "442891", "442888", "442893", "442889"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1993", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "79", "bibliographicPageStart": "73", "bibliographicVolumeNumber": "18", "bibliographic_titles": [{"bibliographic_title": "Medical Dosimetry"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A technique for mapping the spatial dose distributin with a magnetic resonance imager is presented. A ferrous sulphate solution with sulfuric acid was used as the detecting medium for radiation dose. To make a gel of the solution for filling up a cubic phantom, we developed a new gel component that is combined with a super absorbent polymer (Sumikagel N-100) and a cross-linked dextran gel(Sephadex G-200). In order to make the application for radiation treatment planning, mapping of the dose distribution was carried out using a Unix computer.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0958-3947", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Hiraoka, Takeshi"}], "nameIdentifiers": [{"nameIdentifier": "442888", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Katou, Hirotoshi"}], "nameIdentifiers": [{"nameIdentifier": "442889", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tateno, Yukio"}], "nameIdentifiers": [{"nameIdentifier": "442890", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "442891", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平岡 武", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "442892", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "加藤 博敏", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "442893", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "舘野 之男", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "442894", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "A new gel using super absorbent polymer for mapping the spatial dose distributions of electron beams by mr imager", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "A new gel using super absorbent polymer for mapping the spatial dose distributions of electron beams by mr imager"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44597", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-08-28"}, "publish_date": "2006-08-28", "publish_status": "0", "recid": "44597", "relation": {}, "relation_version_is_last": true, "title": ["A new gel using super absorbent polymer for mapping the spatial dose distributions of electron beams by mr imager"], "weko_shared_id": -1}
A new gel using super absorbent polymer for mapping the spatial dose distributions of electron beams by mr imager
https://repo.qst.go.jp/records/44597
https://repo.qst.go.jp/records/44597f5d6b5db-22b5-4076-92b0-a7331fad3766
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-08-28 | |||||
タイトル | ||||||
タイトル | A new gel using super absorbent polymer for mapping the spatial dose distributions of electron beams by mr imager | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Hiraoka, Takeshi
× Hiraoka, Takeshi× Katou, Hirotoshi× Tateno, Yukio× et.al× 平岡 武× 加藤 博敏× 舘野 之男 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A technique for mapping the spatial dose distributin with a magnetic resonance imager is presented. A ferrous sulphate solution with sulfuric acid was used as the detecting medium for radiation dose. To make a gel of the solution for filling up a cubic phantom, we developed a new gel component that is combined with a super absorbent polymer (Sumikagel N-100) and a cross-linked dextran gel(Sephadex G-200). In order to make the application for radiation treatment planning, mapping of the dose distribution was carried out using a Unix computer. | |||||
書誌情報 |
Medical Dosimetry 巻 18, 号 2, p. 73-79, 発行日 1993 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0958-3947 |