{"created":"2023-05-15T14:34:30.932603+00:00","id":44597,"links":{},"metadata":{"_buckets":{"deposit":"40820002-536e-467b-8d9f-a5f7b31017f3"},"_deposit":{"created_by":1,"id":"44597","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"44597"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00044597","sets":["1"]},"author_link":["442890","442892","442894","442891","442888","442893","442889"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1993","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"79","bibliographicPageStart":"73","bibliographicVolumeNumber":"18","bibliographic_titles":[{"bibliographic_title":"Medical Dosimetry"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A technique for mapping the spatial dose distributin with a magnetic resonance imager is presented. A ferrous sulphate solution with sulfuric acid was used as the detecting medium for radiation dose. To make a gel of the solution for filling up a cubic phantom, we developed a new gel component that is combined with a super absorbent polymer (Sumikagel N-100) and a cross-linked dextran gel(Sephadex G-200). In order to make the application for radiation treatment planning, mapping of the dose distribution was carried out using a Unix computer.","subitem_description_type":"Abstract"}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0958-3947","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hiraoka, Takeshi"}],"nameIdentifiers":[{"nameIdentifier":"442888","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Katou, Hirotoshi"}],"nameIdentifiers":[{"nameIdentifier":"442889","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tateno, Yukio"}],"nameIdentifiers":[{"nameIdentifier":"442890","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"et.al"}],"nameIdentifiers":[{"nameIdentifier":"442891","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"平岡 武","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"442892","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"加藤 博敏","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"442893","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"舘野 之男","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"442894","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"A new gel using super absorbent polymer for mapping the spatial dose distributions of electron beams by mr imager","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"A new gel using super absorbent polymer for mapping the spatial dose distributions of electron beams by mr imager"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-08-28"},"publish_date":"2006-08-28","publish_status":"0","recid":"44597","relation_version_is_last":true,"title":["A new gel using super absorbent polymer for mapping the spatial dose distributions of electron beams by mr imager"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:13:35.128120+00:00"}