WEKO3
アイテム
Time course of reoxygenation in experimental murine tumors after carbon-beam and x-ray irradiation
https://repo.qst.go.jp/records/43017
https://repo.qst.go.jp/records/4301731e51a50-b077-4474-a94a-59e31eac64b4
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2002-12-16 | |||||
タイトル | ||||||
タイトル | Time course of reoxygenation in experimental murine tumors after carbon-beam and x-ray irradiation | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Oya, Natsuo
× Oya, Natsuo× Sasai, Keisuke× Shibata, Toru× Takagi, Takehisa× Shibuya, Keiko× Koike, Sachiko× Nojima, Kumie× Furusawa, Yoshiya× Ando, Koichi× Hiraoka, Masahiro× 笹井 啓資× 小池 幸子× 野島 久美恵× 古澤 佳也× 安藤 興一× 平岡 真寛 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We compared the tumor reoxygenation patterns in three different murine tumor cell lines after X-irradiation with those after carbon-beam irradiation using a heavy-ion medical accelerator (HIMAC) system. The tumors of the cell lines SCCVII, SCCVII-variant-1 and EMT6 on the hind legs of mice received local priming irradiation with a carbon-beam (8 Gy, 73 keV/um in LET, 290 MeV/u, 6 cm SOBP) or X-rays (13 Gy, 250 kVp). After various intervals, the mice were given whole-body test irradiation (16 Gy, 250 kVp X-ray) either in air or after they were killed. The hypoxic fractions were estimated as the proportions of the surviving fractions of the tumors in killed mice to those in air-breathing mice. In the SCCVII tumors, the hypoxic fractions at 0.5 h were 50% and 21% (p < 0.05) after the priming X-irradiation and carbon-beam irradiation, respectively. In the SCCVII-variant-1 tumors, the hypoxic fractions were 85% and 82% at 0.5 h, 84% and 20% at 12 h (p < 0.01), and 21% and 31% at 24 h after X-ray and after carbon-beam irradiation, respectively. In the EMT6 tumors, the reoxygenation patterns after X-irradiation and carbon-beam irradiation were quite similar. We concluded that the reoxygenation pattern differed among the three tumor cell lines, and that reoxygenation tended to occur more rapidly after carbon-beam irradiation than after X-irradiation for SCCVII and SCCVII-variant-1tumors. | |||||
書誌情報 |
Journal of Radiation Research 巻 42, p. 131-141, 発行日 2001 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0449-3060 |