量研学術機関リポジトリ「QST-Repository」は、国立研究開発法人 量子科学技術研究開発機構に所属する職員等が生み出した学術成果(学会誌発表論文、学会発表、研究開発報告書、特許等)を集積しインターネット上で広く公開するサービスです。 Welcome to QST-Repository where we accumulates and discloses the academic research results(Journal Publications, Conference presentation, Research and Development Report, Patent, etc.) of the members of National Institutes for Quantum and Radiological Science and Technology.
Thank you very much for using our website. On the 11th of March 2019, this site was moved from our own network server to the JAIRO Cloud network server. If you previously bookmarked this site, that bookmark will no longer work. We would be grateful if you could bookmark the website again. Thank you very much for your understanding and cooperation.
Evaluation of Organ Doses for Pediatric Computed Tomography Using a Newly Designed Radiophotoluminescence Glass Dosimeter and Comparison with a Monte Carlo Simulation-based Dose Calculator
利用統計を見る
Management of patient dose is an effective way to help optimize computed tomography (CT) scanning conditions and CT dose. Organ dose is one of the preferred quantities for radiation protection because of its correlation with radiation risk. To date, the WAZA-ARI dose calculator is the only freely available CT dose calculator also applicable for pediatric patients. However, no reports of its evaluation have appeared since the latest version of WAZA-ARI was released. In this study, to evaluate the latest version of WAZA-ARI, we measured the organ dose in a 5-y-old anthropomorphic phantom by a newly developed radiophotoluminescence glass dosimeter (RGD) dosimetry system and compared these results with the calculation results from WAZA-ARI. The newly designed RGDs have less angular dependence because of the additional filter. RGDs were individually calibrated with the ISOVOLT TITAN-320 x-ray generator. All the experimental measurements for this study were performed using a CT scanner. To consider the difference of CT output between the nominal and actual machine, the measured CTDIair was used to correct the calculation results obtained from WAZA-ARI. After the corrections using the measured CTDIair, the calculation results from WAZA-ARI were relatively lower than the measured results with a range of 8-20%, which corresponds to the dose difference caused by the difference in effective diameter. In conclusion, the calculation accuracy of WAZA-ARI is guaranteed when the normalization factor specific to each CT scanner (CTDIair) and the shape of the phantom are taken into consideration.