{"_buckets": {"deposit": "4a3b2ac4-2bbb-476e-8d47-45c79fad3a99"}, "_deposit": {"created_by": 1, "id": "78030", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "78030"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00078030", "sets": ["1"]}, "author_link": ["1007651", "1007653", "1007649", "1007650", "1007652"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019-12", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "12", "bibliographicPageEnd": "5832", "bibliographicPageStart": "5824", "bibliographicVolumeNumber": "46", "bibliographic_titles": [{"bibliographic_title": "Medical physics"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "PURPOSE: To estimate out-of-field doses during carbon-ion radiotherapy (CIRT) for pediatric cerebellar ependymoma.\nMETHODS: Given that the out-of-field dose of CIRT depends on beam parameters, we set them for treatment of typical pediatric cerebellar ependymoma based on a previous study. The out-of-field dose during CIRT for pediatric cerebellar ependymoma was then estimated using the Particle and Heavy-Ion Transport code System with Monte Carlo simulations and a computational phantom developed at the University of Florida. From the simulation results, out-of-field doses at dose equivalents of passive beam and active scanning beam CIRT were calculated and compared to the secondary neutron-equivalent dose of passive beam CIRT and proton therapy.\nRESULTS: The out-of-field dose equivalent decreases from 1.45 mSv/Gy (relative biological effectiveness - RBE) at the thyroid to 0.06 mSv/Gy (RBE) at the bladder, verifying decay as the distance from the treatment target increases. The out-of-field neutron-equivalent dose in organs per prescribed dose for passive beam CIRT is lower than that for passive beam proton therapy. Moreover, the out-of-field organ dose equivalent per prescribed dose for the active scanning beam CIRT is lower than that for the passive beam CIRT.\nCONCLUSIONS: Active scanning beam CIRT is promising for pediatric cerebellar ependymoma regarding out-of-field exposure, outperforming the comparison radiotherapy modalities.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "John Wiley and Sons, Inc."}]}, "item_8_relation_13": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "31603561", "subitem_relation_type_select": "PMID"}}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1002/mp.13864", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://aapm.onlinelibrary.wiley.com/doi/full/10.1002/mp.13864", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0094-2405", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Matsumoto, Shinnosuke"}], "nameIdentifiers": [{"nameIdentifier": "1007649", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yonai, Shunsuke"}], "nameIdentifiers": [{"nameIdentifier": "1007650", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "E Bolch, Wesley"}], "nameIdentifiers": [{"nameIdentifier": "1007651", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shinnosuke, Matsumoto", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1007652", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shunsuke, Yonai", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1007653", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Monte Carlo study of out-of-field exposure in carbon-ion radiotherapy: Organ doses in pediatric brain tumor treatment.", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Monte Carlo study of out-of-field exposure in carbon-ion radiotherapy: Organ doses in pediatric brain tumor treatment."}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/78030", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-12-17"}, "publish_date": "2019-12-17", "publish_status": "0", "recid": "78030", "relation": {}, "relation_version_is_last": true, "title": ["Monte Carlo study of out-of-field exposure in carbon-ion radiotherapy: Organ doses in pediatric brain tumor treatment."], "weko_shared_id": -1}
Monte Carlo study of out-of-field exposure in carbon-ion radiotherapy: Organ doses in pediatric brain tumor treatment.
https://repo.qst.go.jp/records/78030
https://repo.qst.go.jp/records/7803075860b53-470c-498d-97f3-1663adcd79fa
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-12-17 | |||||
タイトル | ||||||
タイトル | Monte Carlo study of out-of-field exposure in carbon-ion radiotherapy: Organ doses in pediatric brain tumor treatment. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Matsumoto, Shinnosuke
× Matsumoto, Shinnosuke× Yonai, Shunsuke× E Bolch, Wesley× Shinnosuke, Matsumoto× Shunsuke, Yonai |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | PURPOSE: To estimate out-of-field doses during carbon-ion radiotherapy (CIRT) for pediatric cerebellar ependymoma. METHODS: Given that the out-of-field dose of CIRT depends on beam parameters, we set them for treatment of typical pediatric cerebellar ependymoma based on a previous study. The out-of-field dose during CIRT for pediatric cerebellar ependymoma was then estimated using the Particle and Heavy-Ion Transport code System with Monte Carlo simulations and a computational phantom developed at the University of Florida. From the simulation results, out-of-field doses at dose equivalents of passive beam and active scanning beam CIRT were calculated and compared to the secondary neutron-equivalent dose of passive beam CIRT and proton therapy. RESULTS: The out-of-field dose equivalent decreases from 1.45 mSv/Gy (relative biological effectiveness - RBE) at the thyroid to 0.06 mSv/Gy (RBE) at the bladder, verifying decay as the distance from the treatment target increases. The out-of-field neutron-equivalent dose in organs per prescribed dose for passive beam CIRT is lower than that for passive beam proton therapy. Moreover, the out-of-field organ dose equivalent per prescribed dose for the active scanning beam CIRT is lower than that for the passive beam CIRT. CONCLUSIONS: Active scanning beam CIRT is promising for pediatric cerebellar ependymoma regarding out-of-field exposure, outperforming the comparison radiotherapy modalities. |
|||||
書誌情報 |
Medical physics 巻 46, 号 12, p. 5824-5832, 発行日 2019-12 |
|||||
出版者 | ||||||
出版者 | John Wiley and Sons, Inc. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0094-2405 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 31603561 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1002/mp.13864 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://aapm.onlinelibrary.wiley.com/doi/full/10.1002/mp.13864 |