WEKO3
アイテム
{"_buckets": {"deposit": "69cd3cf8-d750-4f01-8b53-38635a727856"}, "_deposit": {"created_by": 1, "id": "67915", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "67915"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00067915", "sets": ["28"]}, "author_link": ["667079", "667081", "667080"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2004-10-22", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A high-performance brain PET scanner, jPET-D4, which provides depth-of-interaction (DOI) information, is under development. The scanner is designed to achieve not only high spatial resolution but also high scanner sensitivity with the DOI information obtained from multi-layered thin crystals. The scanner has 5 rings of 24 detector blocks each, and the detector block consists of 1,024 GSO crystals of 2.9mm x 2.9mm x 7.5mm, which are arranged in 4 layers of 16 x 16 arrays. At this stage, a pair of detector blocks and a coincidence circuit has been assembled into an experimental prototype gantry. In this paper, as a preliminary experiment, we have investigated the performance of the jPET-D4\u0027s inherent spatial resolution and noise characteristics using the prototype system. Spatial resolution and background noise were measured by using a line source and a uniform cylinder phantom respectively. To avoid systematic error and reduce computational cost in image reconstruction, the DOI compression (DOIC) method followed by the ML-EM with accurate system modeling, that we have previously proposed, was applied. Experimental results showed that the jPET-D4 achieves less than 3mm spatial resolution over the field-of-view. Trade-off results between spatial resolution and background noise also promise an excellent performance of the scanner.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "IEEE 2004 Nuclear Science Symposium and Medical Imaging Conference", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yamaya, Taiga"}], "nameIdentifiers": [{"nameIdentifier": "667079", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "667080", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山谷 泰賀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "667081", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Preliminary Performance Evaluation of the Prototype System for a Brain DOI-PET Scanner: jPET-D4", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Preliminary Performance Evaluation of the Prototype System for a Brain DOI-PET Scanner: jPET-D4"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/67915", "pubdate": {"attribute_name": "公開日", "attribute_value": "2004-10-27"}, "publish_date": "2004-10-27", "publish_status": "0", "recid": "67915", "relation": {}, "relation_version_is_last": true, "title": ["Preliminary Performance Evaluation of the Prototype System for a Brain DOI-PET Scanner: jPET-D4"], "weko_shared_id": -1}
Preliminary Performance Evaluation of the Prototype System for a Brain DOI-PET Scanner: jPET-D4
https://repo.qst.go.jp/records/67915
https://repo.qst.go.jp/records/67915b87d7af2-aae3-4ea7-bf0b-f95b3b942f05
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2004-10-27 | |||||
タイトル | ||||||
タイトル | Preliminary Performance Evaluation of the Prototype System for a Brain DOI-PET Scanner: jPET-D4 | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yamaya, Taiga
× Yamaya, Taiga× et.al× 山谷 泰賀 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A high-performance brain PET scanner, jPET-D4, which provides depth-of-interaction (DOI) information, is under development. The scanner is designed to achieve not only high spatial resolution but also high scanner sensitivity with the DOI information obtained from multi-layered thin crystals. The scanner has 5 rings of 24 detector blocks each, and the detector block consists of 1,024 GSO crystals of 2.9mm x 2.9mm x 7.5mm, which are arranged in 4 layers of 16 x 16 arrays. At this stage, a pair of detector blocks and a coincidence circuit has been assembled into an experimental prototype gantry. In this paper, as a preliminary experiment, we have investigated the performance of the jPET-D4's inherent spatial resolution and noise characteristics using the prototype system. Spatial resolution and background noise were measured by using a line source and a uniform cylinder phantom respectively. To avoid systematic error and reduce computational cost in image reconstruction, the DOI compression (DOIC) method followed by the ML-EM with accurate system modeling, that we have previously proposed, was applied. Experimental results showed that the jPET-D4 achieves less than 3mm spatial resolution over the field-of-view. Trade-off results between spatial resolution and background noise also promise an excellent performance of the scanner. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | IEEE 2004 Nuclear Science Symposium and Medical Imaging Conference | |||||
発表年月日 | ||||||
日付 | 2004-10-22 | |||||
日付タイプ | Issued |