量研学術機関リポジトリ「QST-Repository」は、国立研究開発法人 量子科学技術研究開発機構に所属する職員等が生み出した学術成果(学会誌発表論文、学会発表、研究開発報告書、特許等)を集積しインターネット上で広く公開するサービスです。 Welcome to QST-Repository where we accumulates and discloses the academic research results(Journal Publications, Conference presentation, Research and Development Report, Patent, etc.) of the members of National Institutes for Quantum Science and Technology.
Thank you very much for using our website. On the 11th of March 2019, this site was moved from our own network server to the JAIRO Cloud network server. If you previously bookmarked this site, that bookmark will no longer work. We would be grateful if you could bookmark the website again. Thank you very much for your understanding and cooperation.
Background
The purpose of this study was to present our evaluation of the safety and efficacy of carbon-ion radiotherapy (C-ion RT) for locally advanced parotid gland carcinomas.
Methods
Clinicopathological features and outcomes were evaluated in 46 patients receiving C-ion RT for parotid gland carcinomas.
Results
Sixteen patients had adenoid cystic carcinoma; 8 had adenocarcinoma, 8 had mucoepidermoid carcinoma, and 14 had other carcinomas. T2, T3, T4a, and T4b diseases were diagnosed in 3, 18, 8, and 17 patients, respectively. C-ion RT was provided to 25 patients as the primary treatment, to 20 patients for local recurrences after surgery, and to 1 patient for residual tumor after surgery. During follow-up (median duration, 62 months), 5-year local control and overall survival (OS) rates were 74.5% and 70.1%, respectively. Of the 30 patients without facial nerve palsy before C-ion RT, 25 showed no radiation-induced facial nerve palsy.