WEKO3
アイテム
{"_buckets": {"deposit": "b152a596-bacd-42be-9d58-2b74f833486a"}, "_deposit": {"created_by": 1, "id": "45825", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "45825"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00045825", "sets": ["1"]}, "author_link": ["455678", "455677", "455676", "455679", "455675"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "199", "bibliographicPageStart": "193", "bibliographicVolumeNumber": "27", "bibliographic_titles": [{"bibliographic_title": "Medical Imaging Technology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "4次元CT画像から肺内部の特徴点を追跡し,肺動態を定量化する新しい手法について提案する.提案手法は,動態追跡の一手法であるKLT tarcker を3 次元に拡張した3D-KLT tracker を用いる.追跡のための特徴点(特徴領域)は画像の1 次微分値のみを考慮した単純なエッジの抽出を行うため,従来法で特徴点とされてきた気管支や血管領域に限定されない多くの点を自動で抽出できるという利点がある.また,ピラミッド画像を用いた階層的トラッキングを行ったことにより,特徴領域が小さい場合も対象物体の大きな変位の追跡が可能となった.肺の多くの特徴点を追跡することにより肺動態定量化を行う.本稿では,人為的に作った4 次元CT 画像に対する提案手法のトラッキング性能評価結果および実際の患者の4 次元CT 画像を用いた動態定量化結果について示す.実験より,特徴点は単純な平行移動ではなく,楕円形を描くように変位することが明らかとなった.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0288-450X", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "久保田, 佳樹"}], "nameIdentifiers": [{"nameIdentifier": "455675", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "青木, 工太"}], "nameIdentifiers": [{"nameIdentifier": "455676", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "長橋, 宏"}], "nameIdentifiers": [{"nameIdentifier": "455677", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "蓑原, 伸一"}], "nameIdentifiers": [{"nameIdentifier": "455678", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "蓑原 伸一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "455679", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "3D-KLT tracker を用いた4 次元CT 画像からの肺動態の定量化", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "3D-KLT tracker を用いた4 次元CT 画像からの肺動態の定量化"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/45825", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-06-16"}, "publish_date": "2010-06-16", "publish_status": "0", "recid": "45825", "relation": {}, "relation_version_is_last": true, "title": ["3D-KLT tracker を用いた4 次元CT 画像からの肺動態の定量化"], "weko_shared_id": -1}
3D-KLT tracker を用いた4 次元CT 画像からの肺動態の定量化
https://repo.qst.go.jp/records/45825
https://repo.qst.go.jp/records/4582531045045-8be2-4880-aa23-de688621155a
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-06-16 | |||||
タイトル | ||||||
タイトル | 3D-KLT tracker を用いた4 次元CT 画像からの肺動態の定量化 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
久保田, 佳樹
× 久保田, 佳樹× 青木, 工太× 長橋, 宏× 蓑原, 伸一× 蓑原 伸一 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 4次元CT画像から肺内部の特徴点を追跡し,肺動態を定量化する新しい手法について提案する.提案手法は,動態追跡の一手法であるKLT tarcker を3 次元に拡張した3D-KLT tracker を用いる.追跡のための特徴点(特徴領域)は画像の1 次微分値のみを考慮した単純なエッジの抽出を行うため,従来法で特徴点とされてきた気管支や血管領域に限定されない多くの点を自動で抽出できるという利点がある.また,ピラミッド画像を用いた階層的トラッキングを行ったことにより,特徴領域が小さい場合も対象物体の大きな変位の追跡が可能となった.肺の多くの特徴点を追跡することにより肺動態定量化を行う.本稿では,人為的に作った4 次元CT 画像に対する提案手法のトラッキング性能評価結果および実際の患者の4 次元CT 画像を用いた動態定量化結果について示す.実験より,特徴点は単純な平行移動ではなく,楕円形を描くように変位することが明らかとなった. | |||||
書誌情報 |
Medical Imaging Technology 巻 27, 号 3, p. 193-199, 発行日 2009-03 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0288-450X |