{"created":"2023-05-15T15:03:34.111662+00:00","id":86123,"links":{},"metadata":{"_buckets":{"deposit":"e63acbf0-6a9b-4ca1-9895-462decb5e752"},"_deposit":{"created_by":1,"id":"86123","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"86123"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00086123","sets":["7"]},"author_link":["1046194","1046195"],"item_10004_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2022-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"91","bibliographicPageStart":"85","bibliographicVolumeNumber":"71","bibliographic_titles":[{"bibliographic_title":"RADIOISOTOPES"}]}]},"item_10004_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"γ線・電子線による放射線照射施設の工程・品質管理の手段として, 吸収線量測定は重要な技術である。照射効果の最適化には正確な吸収線量評価が必要不可欠となっている。ここでは, 線量域毎の利用分野, 照射施設における1Gy以上の吸収線量測定の線量計の種類と適用範囲を概説する。さらに大線量計測の国際動向と今後の課題について述べる。","subitem_description_type":"Abstract"}]},"item_10004_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"公益社団法人日本アイソトープ協会"}]},"item_10004_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/article/radioisotopes/71/2/71_710203/_article/-char/ja","subitem_relation_type_select":"URI"}}]},"item_10004_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0033-8303","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"清藤, 一"}],"nameIdentifiers":[{"nameIdentifier":"1046194","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hajime, Seito","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1046195","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"放射線照射施設における吸収線量測定","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"放射線照射施設における吸収線量測定"}]},"item_type_id":"10004","owner":"1","path":["7"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-11-25"},"publish_date":"2021-11-25","publish_status":"0","recid":"86123","relation_version_is_last":true,"title":["放射線照射施設における吸収線量測定"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T17:14:48.170168+00:00"}