{"created":"2023-05-15T15:03:19.347561+00:00","id":85778,"links":{},"metadata":{"_buckets":{"deposit":"2d7797ff-e03e-43b9-8cc9-634c68ca9a18"},"_deposit":{"created_by":1,"id":"85778","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"85778"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00085778","sets":["10:29"]},"author_link":["1032933","1032936","1032932","1032935","1032934","1032938","1032931","1032937"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2022-03-26","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"ラジオフォトルミネッセンス(RPL)を原理とした線量計として知られる銀活性リン酸塩ガラスを用いて、蛍光イオントラック計測に関する特性を評価した。HIMACにおいて照射した重粒子線の蛍光イオントラックを共焦点顕微鏡により測定した。LET(線エネルギー付与)の下限は5 keV/µm(水換算)程度であり、閾値型の高LET粒子検出器として動作する可能性があり、例えば宇宙放射線計測への応用が考えられる。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第34回固体飛跡検出器研究会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"小平, 聡"}],"nameIdentifiers":[{"nameIdentifier":"1032931","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"楠本, 多聞"}],"nameIdentifiers":[{"nameIdentifier":"1032932","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北村, 尚"}],"nameIdentifiers":[{"nameIdentifier":"1032933","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"柳田, 由香"}],"nameIdentifiers":[{"nameIdentifier":"1032934","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小口, 靖弘"}],"nameIdentifiers":[{"nameIdentifier":"1032935","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Satoshi, Kodaira","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1032936","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tamon, Kusumoto","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1032937","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hisashi, Kitamura","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1032938","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"銀活性リン酸塩ガラスを用いた蛍光イオントラック計測","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"銀活性リン酸塩ガラスを用いた蛍光イオントラック計測"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-03-28"},"publish_date":"2022-03-28","publish_status":"0","recid":"85778","relation_version_is_last":true,"title":["銀活性リン酸塩ガラスを用いた蛍光イオントラック計測"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T17:37:09.361810+00:00"}