{"created":"2023-05-15T15:03:13.371298+00:00","id":85642,"links":{},"metadata":{"_buckets":{"deposit":"a54059a6-7be4-410b-ae90-1a745358eaab"},"_deposit":{"created_by":1,"id":"85642","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"85642"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00085642","sets":["1"]},"author_link":["1030945","1030949","1030950","1030951","1030952","1030944","1030948","1030946","1030947","1030943"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2021-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"6","bibliographicPageEnd":"416","bibliographicPageStart":"414","bibliographicVolumeNumber":"9","bibliographic_titles":[{"bibliographic_title":"SPring-8/SACLA利用研究成果集"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"ヒドラジン酸化触媒であるNi系担持カーボン触媒において溶液中でのヒドラジン酸化反応種であるヒドラジンや水酸化物イオンの表面吸着状態を解析するため、in-situ XAFS測定を行った。その結果、活性の高い触媒は、触媒表面に水分子が吸着しにくいことが示唆された。さらに詳細に解析するために高分解能XAFS測定にチャレンジしたが、通常型XAFSよりも高い光強度による触媒への影響があり、測定セルの改良が必要であることが明らかになった。","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"公益財団法人 高輝度光科学研究センター"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.18957/rr.9.6.414","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/article/springresrep/9/6/9_414/_article/-char/ja/","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":" 2187-6886","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"吉元, 光児"}],"nameIdentifiers":[{"nameIdentifier":"1030943","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"西野, 英里子"}],"nameIdentifiers":[{"nameIdentifier":"1030944","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"坂本, 友和"}],"nameIdentifiers":[{"nameIdentifier":"1030945","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"加藤, 豪士"}],"nameIdentifiers":[{"nameIdentifier":"1030946","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"草野, 翔吾"}],"nameIdentifiers":[{"nameIdentifier":"1030947","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"水木, 純一郎"}],"nameIdentifiers":[{"nameIdentifier":"1030948","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松村, 大樹"}],"nameIdentifiers":[{"nameIdentifier":"1030949","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石井, 賢司"}],"nameIdentifiers":[{"nameIdentifier":"1030950","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Junichiro, Mizuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1030951","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kenji, Ishii","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1030952","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"ヒドラジン酸化触媒のIn-situ XAFS測定","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ヒドラジン酸化触媒のIn-situ XAFS測定"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-02-17"},"publish_date":"2022-02-17","publish_status":"0","recid":"85642","relation_version_is_last":true,"title":["ヒドラジン酸化触媒のIn-situ XAFS測定"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T17:42:03.020995+00:00"}