{"created":"2023-05-15T15:03:05.426811+00:00","id":85468,"links":{},"metadata":{"_buckets":{"deposit":"db16c778-262d-4884-81e8-3653093b043b"},"_deposit":{"created_by":1,"id":"85468","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"85468"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00085468","sets":["1"]},"author_link":["1047192","1047187","1047185","1047189","1047184","1047179","1047180","1047190","1047191","1047181","1047183","1047186","1047182","1047188"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2022-03","bibliographicIssueDateType":"Issued"},"bibliographic_titles":[{"bibliographic_title":"日本診療放射線技師会誌"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"1.放射線測定器着用:100%ではなく、着用促しも不十分\n「100%着用しているので該当事例なし」は7%のみ。「頻繁に促している」のは20%のみ。促せない理由:「医師には言いづらい」56%、「他部署には言いづらい」28%\n2.水晶体専用放射線測定器を配布していない施設の割合\nすべて診療科等で60%台。良好着用率は平均14%\n3.防護眼鏡着用率に課題有\n•良好着用率:循環器内科医55%、放射線科医(IVR)75%、消化器外科医13%と整形外科医12%\n4.防護眼鏡不足施設率:Vascular-IVR室24%\n5.X線装置設置内視鏡室に防護クロス「ない」47%","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"渡邉, 浩"}],"nameIdentifiers":[{"nameIdentifier":"1047179","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山本, 和幸"}],"nameIdentifiers":[{"nameIdentifier":"1047180","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"坂本, 肇"}],"nameIdentifiers":[{"nameIdentifier":"1047181","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"今尾, 仁"}],"nameIdentifiers":[{"nameIdentifier":"1047182","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"瀬下, 幸彦"}],"nameIdentifiers":[{"nameIdentifier":"1047183","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"加藤, 英幸"}],"nameIdentifiers":[{"nameIdentifier":"1047184","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"竹中, 完"}],"nameIdentifiers":[{"nameIdentifier":"1047185","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"赤羽, 恵一"}],"nameIdentifiers":[{"nameIdentifier":"1047186","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"神田, 玲子"}],"nameIdentifiers":[{"nameIdentifier":"1047187","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鳥巣, 健二"}],"nameIdentifiers":[{"nameIdentifier":"1047188","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"三上, 容司"}],"nameIdentifiers":[{"nameIdentifier":"1047189","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"細野 眞"}],"nameIdentifiers":[{"nameIdentifier":"1047190","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Keiichi, Akahane","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1047191","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Reiko, Kanda","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1047192","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"医療機関における放射線業務従事者への個人線量計および放射線防護機材の配布ならびに着用状況等に関する調査報告","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"医療機関における放射線業務従事者への個人線量計および放射線防護機材の配布ならびに着用状況等に関する調査報告"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-03-18"},"publish_date":"2022-03-18","publish_status":"0","recid":"85468","relation_version_is_last":true,"title":["医療機関における放射線業務従事者への個人線量計および放射線防護機材の配布ならびに着用状況等に関する調査報告"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T17:13:14.491286+00:00"}