{"created":"2023-05-15T15:02:41.534528+00:00","id":84999,"links":{},"metadata":{"_buckets":{"deposit":"4c989d4e-6037-4f0c-94b6-5abf61be3313"},"_deposit":{"created_by":1,"id":"84999","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"84999"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00084999","sets":["1"]},"author_link":["1043119","1043120","1043125","1043121","1043126","1043124","1043128","1043123","1043122","1043127"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2022-02","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"49","bibliographicPageStart":"39","bibliographicVolumeNumber":"47","bibliographic_titles":[{"bibliographic_title":"Journal of Radiation Protection and Research"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We have been investigating to properly evaluate personal dose equivalent for the lens of the eye, Hp(3) of highly exposed medical staffs. One of the key parameters is the mean X-ray energy which medical staff may receive around their eyes, because the response of the dosimeter is strongly dependent on incident X-ray energy. However, there is a few studies which experimentally investigated scattered X-rays that medical staff actually encounters during their procedures. The scattered X-rays from X-ray diagnosis and therapeutic equipment was measured using the CdTeZn spectrometer. Derived results indicated that the mean X-ray energies ranged between 40 keV and 60 keV. The measurement results also support that the reduction effect on the eye lens dose due to the protection glasses or ceiling-suspended shield was experimentally evaluated from the pulse height spectra.","subitem_description_type":"Abstract"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.14407/jrpr.2021.00220","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.14407/jrpr.2021.00220","subitem_relation_type_select":"DOI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2508-1888","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Munehiko, Kowatari"}],"nameIdentifiers":[{"nameIdentifier":"1043119","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nagamoto, Keisuke"}],"nameIdentifiers":[{"nameIdentifier":"1043120","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nakagami, Koich"}],"nameIdentifiers":[{"nameIdentifier":"1043121","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tanimura, Yoshihiko"}],"nameIdentifiers":[{"nameIdentifier":"1043122","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takashi, Moritake"}],"nameIdentifiers":[{"nameIdentifier":"1043123","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kunugita, Naoki"}],"nameIdentifiers":[{"nameIdentifier":"1043124","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Munehiko, Kowatari","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1043125","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Koichi, Nakagami","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1043126","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takashi, Moritake","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1043127","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Naoki, Kunugita","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1043128","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Experimental evaluation of scattered X-ray spectra due to X-ray therapeutic and diagnosis equipment for eye lens dosimetry of medical staff","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Experimental evaluation of scattered X-ray spectra due to X-ray therapeutic and diagnosis equipment for eye lens dosimetry of medical staff"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-02-22"},"publish_date":"2022-02-22","publish_status":"0","recid":"84999","relation_version_is_last":true,"title":["Experimental evaluation of scattered X-ray spectra due to X-ray therapeutic and diagnosis equipment for eye lens dosimetry of medical staff"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T17:20:30.745683+00:00"}