{"created":"2023-05-15T15:02:39.305569+00:00","id":84950,"links":{},"metadata":{"_buckets":{"deposit":"153fc4ae-ba71-4361-82bb-a74a768aa582"},"_deposit":{"created_by":1,"id":"84950","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"84950"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00084950","sets":["1"]},"author_link":["1043386","1043388","1043393","1043387","1043391","1043394","1043395","1043389","1043392","1043390","1043385","1043383","1043384"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2022-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"e81","bibliographicPageStart":"e50","bibliographicVolumeNumber":"49","bibliographic_titles":[{"bibliographic_title":"Medical Physics"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Dose uncertainty induced by respiratory motion remains a major concern for treating thoracic and abdominal lesions using particle beams. This Task Group report reviews the impact of tumor motion and dosimetric considerations in particle radiotherapy, current motion-management techniques, and limitations for different particle-beam delivery modes (i.e., passive scattering, uniform scanning, and pencil-beam scanning). Furthermore, the report provides guidance and risk analysis for quality assurance of the motion-management procedures to ensure consistency and accuracy, and discusses future development and emerging motion-management strategies. This report supplements previously published AAPM report TG76, and considers aspects of motion management that are crucial to the accurate and safe delivery of particle-beam therapy. To that end, this report produces general recommendations for commissioning and facility-specific dosimetric characterization, motion assessment, treatment planning, active and passive motion-management techniques, image guidance and related decision-making, monitoring throughout therapy, and recommendations for vendors. Key among these recommendations are that: 1) facilities should perform thorough planning studies (using retrospective data) and develop standard operating procedures that address all aspects of therapy for any treatment site involving respiratory motion; 2) a risk-based methodology should be adopted for quality management and ongoing process improvement.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Wiley"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1002/mp.15470","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.15470","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0094-2405","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Li, Heng"}],"nameIdentifiers":[{"nameIdentifier":"1043383","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Dong, Lei"}],"nameIdentifiers":[{"nameIdentifier":"1043384","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Christoph Bert"}],"nameIdentifiers":[{"nameIdentifier":"1043385","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Joe Chang"}],"nameIdentifiers":[{"nameIdentifier":"1043386","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Stella Flampouri"}],"nameIdentifiers":[{"nameIdentifier":"1043387","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kyung-Wook Jee"}],"nameIdentifiers":[{"nameIdentifier":"1043388","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Liyong Lin"}],"nameIdentifiers":[{"nameIdentifier":"1043389","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Moyers, Michael"}],"nameIdentifiers":[{"nameIdentifier":"1043390","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shinichiro, Mori"}],"nameIdentifiers":[{"nameIdentifier":"1043391","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Joerg Rottmann"}],"nameIdentifiers":[{"nameIdentifier":"1043392","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Erik Tryggestad"}],"nameIdentifiers":[{"nameIdentifier":"1043393","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Vedam, Sastry"}],"nameIdentifiers":[{"nameIdentifier":"1043394","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shinichiro, Mori","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1043395","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Report of AAPM Task Group 290: Respiratory motion management for particle therapy","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Report of AAPM Task Group 290: Respiratory motion management for particle therapy"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-01-27"},"publish_date":"2022-01-27","publish_status":"0","recid":"84950","relation_version_is_last":true,"title":["Report of AAPM Task Group 290: Respiratory motion management for particle therapy"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T17:19:55.441486+00:00"}