{"created":"2023-05-15T15:02:32.371558+00:00","id":84798,"links":{},"metadata":{"_buckets":{"deposit":"2aa9f5df-40a7-422e-8d6e-9f0241e827eb"},"_deposit":{"created_by":1,"id":"84798","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"84798"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00084798","sets":["1"]},"author_link":["1023165","1023166","1023168","1023170","1023177","1023176","1023175","1023164","1023163","1023172","1023174","1023178","1023162","1023180","1023169","1023179","1023171","1023173","1023167"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2021-10","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"112903","bibliographicVolumeNumber":"173","bibliographic_titles":[{"bibliographic_title":"Fusion Engineering and Design "}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"ITER (International Thermonuclear Experimental Reactor) is a nuclear fusion research and engineering project. It\nis supposed to be the first fusion device to test the integrated technologies, materials and operational regimes\nnecessary for the commercial production of fusion-based electricity. Front (explored in this paper) and Back\ndiagnostic racks are used as supporting structures of the so-called ITER Divertor Thomson Scattering (DTS)\nDiagnostic System that is created to measure plasma characteristics. They will be attached to the lower port walls\n(ITER ports are used to locate diagnostic equipment and its supporting structures) through the so-called Divertor\nRails. The developed design of the Front (Diagnostic) Rack locking (e.g. Rack attachment to the rails mechanism)\nwas analyzed in this research to be consistent with thermal stresses, electromagnetic and seismic loads taking\ninto account some specific assembly and maintenance loads including preloading under installation. The analysis\nof the rack locking design’s resistance to the mentioned loads should prove correspondence of the suggested\ncommon rack design with the structure integrity criterions. Construction strength under the most severe loading\nscenario was estimated in this research and appropriate conclusions were made. It was found out that the stress\ncriterion was not fully satisfied, so a new rack locking design concept was proposed. Its main details are also\ndescribed at the end of this article.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Elsevier B.V."}]},"item_8_relation_13":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"PubMed-ID","subitem_relation_type_select":"PMID"}}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1016/j.fusengdes.2021.112903","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.sciencedirect.com/science/article/pii/S0920379621006797","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0920-3796","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Buslakov, I.V."}],"nameIdentifiers":[{"nameIdentifier":"1023162","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kirienko, I.D."}],"nameIdentifiers":[{"nameIdentifier":"1023163","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Modestov, V.S."}],"nameIdentifiers":[{"nameIdentifier":"1023164","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Loginov, I.N."}],"nameIdentifiers":[{"nameIdentifier":"1023165","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Senichenkov, V.A."}],"nameIdentifiers":[{"nameIdentifier":"1023166","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"E. Mukhin, E."}],"nameIdentifiers":[{"nameIdentifier":"1023167","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Litvinov, A.E."}],"nameIdentifiers":[{"nameIdentifier":"1023168","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Babinov, N.A."}],"nameIdentifiers":[{"nameIdentifier":"1023169","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tolstyakov, S.Yu."}],"nameIdentifiers":[{"nameIdentifier":"1023170","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Chernakov, P.V."}],"nameIdentifiers":[{"nameIdentifier":"1023171","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Marinin, G.V."}],"nameIdentifiers":[{"nameIdentifier":"1023172","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Terentiev, D.V."}],"nameIdentifiers":[{"nameIdentifier":"1023173","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Bulkin, R.S."}],"nameIdentifiers":[{"nameIdentifier":"1023174","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Pashkovsky, S.M."}],"nameIdentifiers":[{"nameIdentifier":"1023175","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mokeev, A.N."}],"nameIdentifiers":[{"nameIdentifier":"1023176","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tanaka, S."}],"nameIdentifiers":[{"nameIdentifier":"1023177","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Andrew, P."}],"nameIdentifiers":[{"nameIdentifier":"1023178","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nagy, D."}],"nameIdentifiers":[{"nameIdentifier":"1023179","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Suguru, Tanaka","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1023180","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Structural analysis of the diagnostic rack locking in ITER lower port #8","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Structural analysis of the diagnostic rack locking in ITER lower port #8"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-12-15"},"publish_date":"2021-12-15","publish_status":"0","recid":"84798","relation_version_is_last":true,"title":["Structural analysis of the diagnostic rack locking in ITER lower port #8"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T18:11:28.155192+00:00"}