{"created":"2023-05-15T15:02:25.048798+00:00","id":84633,"links":{},"metadata":{"_buckets":{"deposit":"72847797-0543-4e37-90d2-8c68ed53c76c"},"_deposit":{"created_by":1,"id":"84633","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"84633"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00084633","sets":["10:28"]},"author_link":["1021451","1021448","1021454","1021455","1021449","1021446","1021456","1021450","1021453","1021447","1021452","1021445"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2022-01-09","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"試料微小空間の電子バンド構造の可視化を可能にし、国内放射光を用いた AREPS 研究をさらに高度化すべく、Photon Factory のBL-28A において真空紫外領域用のKB ミラーを製作し、これをDA30アナライザーの直前に敷設した結果、測定焦点上で12 μm (H) × 15 μm (V)の微小スポットを得ることに成功した。また試料マニピュレーターに光学式エンコーダーを設置し、アナライザーとマニピュレーターの同期制御を行い、試料から射出した光電子の空間分布を測定することに成功した。","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"第35回日本放射光学会年会・放射光科学合同シンポジウム","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"相馬, 清吾"}],"nameIdentifiers":[{"nameIdentifier":"1021445","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"本間, 飛鳥"}],"nameIdentifiers":[{"nameIdentifier":"1021446","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北村, 未歩"}],"nameIdentifiers":[{"nameIdentifier":"1021447","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"堀場, 弘司"}],"nameIdentifiers":[{"nameIdentifier":"1021448","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"川上, ⻯平"}],"nameIdentifiers":[{"nameIdentifier":"1021449","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"渡辺, 夏芽"}],"nameIdentifiers":[{"nameIdentifier":"1021450","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中山, 耕輔"}],"nameIdentifiers":[{"nameIdentifier":"1021451","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"菅原, 克明"}],"nameIdentifiers":[{"nameIdentifier":"1021452","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高橋, 隆"}],"nameIdentifiers":[{"nameIdentifier":"1021453","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"組頭, 広志"}],"nameIdentifiers":[{"nameIdentifier":"1021454","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐藤, 宇史"}],"nameIdentifiers":[{"nameIdentifier":"1021455","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Koji, Horiba","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1021456","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"マイクロARPESによるトポロジカル物質の局所電子状態","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"マイクロARPESによるトポロジカル物質の局所電子状態"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-01-05"},"publish_date":"2022-01-05","publish_status":"0","recid":"84633","relation_version_is_last":true,"title":["マイクロARPESによるトポロジカル物質の局所電子状態"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T18:17:53.256263+00:00"}