{"created":"2023-05-15T15:01:57.488974+00:00","id":84037,"links":{},"metadata":{"_buckets":{"deposit":"ca6e89d9-5f0b-41ca-8ccb-3a85f4b88cc2"},"_deposit":{"created_by":1,"id":"84037","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"84037"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00084037","sets":["1"]},"author_link":["1014930","1014935","1014947","1014928","1014932","1014925","1014931","1014934","1014937","1014940","1014929","1014948","1014942","1014926","1014936","1014927","1014945","1014939","1014938","1014941","1014943","1014946","1014933","1014944"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2021-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"9","bibliographicPageEnd":"3606","bibliographicPageStart":"3598","bibliographicVolumeNumber":"112","bibliographic_titles":[{"bibliographic_title":"Cancer science"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"There are no clinical reports of long-term follow-up after carbon-ion radiotherapy (CIRT) using a dose of 51.6 Gy (relative biological effectiveness [RBE]) in 12 fractions for localized prostate cancer, or of a comparison of clinical outcomes between passive and scanning beam irradiation. A total of 256 patients with localized prostate cancer who received CIRT at a dose of 51.6 Gy (RBE) in 12 fractions using two different beam delivery techniques (passive [n = 45] and scanning [n = 211]), and who were followed for more than 1 year, were analyzed. The biochemical relapse-free (bRF) rate was defined by the Phoenix definition, and the actuarial toxicity rates were evaluated using the Kaplan-Meier method. Of the 256 patients, 41 (16.0%), 111 (43.4%), and 104 (40.6%) were classified as low, intermediate, and high risk, respectively, after a median follow-up of 7.0 (range 1.1-10.4) years. Androgen deprivation therapy was performed in 212 patients (82.8%). The 5-year bRF rates of the low-, intermediate-, and high-risk patients were 95.1%, 90.9%, and 91.1%, respectively. The 5-year rates of grade 2 late gastrointestinal and genitourinary toxicities in all patients were 0.4% and 6.3%, respectively. No grade ≥3 toxicities were observed. There were no significant differences in the rates of bRF or grade 2 toxicities in patients who received passive irradiation versus scanning irradiation. Our long-term follow-up results showed that a CIRT regimen of 51.6 Gy (RBE) in 12 fractions for localized prostate cancer yielded a good therapeutic outcome and low toxicity rates irrespective of the beam delivery technique.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Wiley "}]},"item_8_relation_13":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"34107139","subitem_relation_type_select":"PMID"}}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1111/cas.15019","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://onlinelibrary.wiley.com/doi/full/10.1111/cas.15019","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1347-9032","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Sato, Hiraku"}],"nameIdentifiers":[{"nameIdentifier":"1014925","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kasuya, Goro"}],"nameIdentifiers":[{"nameIdentifier":"1014926","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ishikawa, Hitoshi"}],"nameIdentifiers":[{"nameIdentifier":"1014927","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nomoto, Akihiro"}],"nameIdentifiers":[{"nameIdentifier":"1014928","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ono, Takashi"}],"nameIdentifiers":[{"nameIdentifier":"1014929","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nakajima, Mio"}],"nameIdentifiers":[{"nameIdentifier":"1014930","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Isozaki, Yuka"}],"nameIdentifiers":[{"nameIdentifier":"1014931","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamamoto, Naoyoshi"}],"nameIdentifiers":[{"nameIdentifier":"1014932","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Iwai, Yuma"}],"nameIdentifiers":[{"nameIdentifier":"1014933","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nemoto, Kenji"}],"nameIdentifiers":[{"nameIdentifier":"1014934","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ichikawa, Tomohiko"}],"nameIdentifiers":[{"nameIdentifier":"1014935","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tsuji, Hiroshi"}],"nameIdentifiers":[{"nameIdentifier":"1014936","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hiraku, Sato","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1014937","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Goro, Kasuya","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1014938","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hitoshi, Ishikawa","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1014939","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Akihiro, Nomoto","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1014940","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takashi, Ono","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1014941","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mio, Nakajima","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1014942","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yuka, Isozaki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1014943","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Naoyoshi, Yamamoto","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1014944","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yuma, Iwai","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1014945","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kenji, Nemoto","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1014946","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ichikawa, Tomohiko","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1014947","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hiroshi, Tsuji","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1014948","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Long-term clinical outcomes after 12-fractionated carbon-ion radiotherapy for localized prostate cancer","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Long-term clinical outcomes after 12-fractionated carbon-ion radiotherapy for localized prostate cancer"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-07-14"},"publish_date":"2021-07-14","publish_status":"0","recid":"84037","relation_version_is_last":true,"title":["Long-term clinical outcomes after 12-fractionated carbon-ion radiotherapy for localized prostate cancer"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T18:45:03.314412+00:00"}