{"created":"2023-05-15T15:00:50.978071+00:00","id":82543,"links":{},"metadata":{"_buckets":{"deposit":"7ff94a81-24f1-4ad6-a55f-998615b735f6"},"_deposit":{"created_by":1,"id":"82543","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"82543"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00082543","sets":["10:29"]},"author_link":["942280","942288","942279","942286","942287","942289","942284","942285","942281","942290","942283","942282"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2021-03-18","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Combining the Nuclear Resonance Fluorescence (NRF) transmission method with computed to-mography (CT) can be a novel method for imaging the isotope distributions, which is indispensable in nuclear engineering. We performed an experiment to reconstruct a three-dimensional NRF–CT image, with isotope selectivity, of enriched lead isotope rods (208Pb) together with a set of different rods, including another enriched isotope (206Pb), iron, and aluminum rods, inserted into an alu-minum cylindrical holder. Using a laser Compton scattering (LCS) gamma-ray beam at UVSOR-III we excited the J????=1- NRF level at 5.512 MeV in 208Pb.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"日本原子力学会 2021年春の年会","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Ali, Khaled"}],"nameIdentifiers":[{"nameIdentifier":"942279","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ohgaki, Hideaki"}],"nameIdentifiers":[{"nameIdentifier":"942280","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Zen, Heishun"}],"nameIdentifiers":[{"nameIdentifier":"942281","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kii, Toshiteru"}],"nameIdentifiers":[{"nameIdentifier":"942282","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hayakawa, Takehito"}],"nameIdentifiers":[{"nameIdentifier":"942283","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shizuma, Toshiyuki"}],"nameIdentifiers":[{"nameIdentifier":"942284","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Toyokawa, Hiroyuki"}],"nameIdentifiers":[{"nameIdentifier":"942285","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Katoh, Masahiro"}],"nameIdentifiers":[{"nameIdentifier":"942286","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Fujimoto, Masaki"}],"nameIdentifiers":[{"nameIdentifier":"942287","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Taira, Yoshitaka"}],"nameIdentifiers":[{"nameIdentifier":"942288","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takehito, Hayakawa","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"942289","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Toshiyuki, Shizuma","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"942290","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Three-Dimensional Nondestructive Isotope-Selective Tomo-graphic Imaging of 208Pb distribution via Nuclear Resonance Fluorescence","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Three-Dimensional Nondestructive Isotope-Selective Tomo-graphic Imaging of 208Pb distribution via Nuclear Resonance Fluorescence"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-03-17"},"publish_date":"2021-03-17","publish_status":"0","recid":"82543","relation_version_is_last":true,"title":["Three-Dimensional Nondestructive Isotope-Selective Tomo-graphic Imaging of 208Pb distribution via Nuclear Resonance Fluorescence"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:20:09.556872+00:00"}