{"created":"2023-05-15T15:00:32.251218+00:00","id":82156,"links":{},"metadata":{"_buckets":{"deposit":"ba2aaa25-b11a-4f44-b927-7b74d698277b"},"_deposit":{"created_by":1,"id":"82156","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"82156"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00082156","sets":["10:29"]},"author_link":["934600","934603","934598","934601","934599","934596","934602","934597"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2020-12-17","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We perform the EDMR (electrically detected magnetic resonance) measurements of the ensemble of NV centers around zero bias voltage to study the influences of the electrical fields generated by the bias voltages on the sensitivity of the NV-diamond magnetometry.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"3rd IFQMS","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Morishita, Hiroki"}],"nameIdentifiers":[{"nameIdentifier":"934596","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nishikawa, Testuri"}],"nameIdentifiers":[{"nameIdentifier":"934597","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shinobu, Onoda"}],"nameIdentifiers":[{"nameIdentifier":"934598","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hiroshi, Abe"}],"nameIdentifiers":[{"nameIdentifier":"934599","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takeshi, Ohshima"}],"nameIdentifiers":[{"nameIdentifier":"934600","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shinobu, Onoda","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"934601","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hiroshi, Abe","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"934602","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takeshi, Ohshima","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"934603","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Electrical Detection of Magnetic Resonance of NV Centers in Diamond Around Zero Bias Voltage","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Electrical Detection of Magnetic Resonance of NV Centers in Diamond Around Zero Bias Voltage"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-03-15"},"publish_date":"2021-03-15","publish_status":"0","recid":"82156","relation_version_is_last":true,"title":["Electrical Detection of Magnetic Resonance of NV Centers in Diamond Around Zero Bias Voltage"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T20:33:59.579547+00:00"}