{"created":"2023-05-15T15:00:19.901370+00:00","id":81878,"links":{},"metadata":{"_buckets":{"deposit":"97abedbb-6028-497c-99ec-69cf7b732097"},"_deposit":{"created_by":1,"id":"81878","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"81878"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00081878","sets":["1"]},"author_link":["1008715","1008714","1008713","1008716"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2021-02","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"472","bibliographicPageStart":"460","bibliographicVolumeNumber":"192","bibliographic_titles":[{"bibliographic_title":"radiation protection dosimetry"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A commercially available active extremity dosemeter is a promising candidate for medical staff aid individual monitoring of the\neye lens. We investigated the applicability of the newly developed active extremity dosemeter, which uses a low-energy photon\nprobe, to eye lens dose monitoring by performing a complete characterization of the dosemeters. Performance tests revealed\nthat the active extremity dosemeter would overestimate personal dose equivalent, Hp(3), when the probe is worn close to the\nlens of the eye of a medial worker without any improvement in the response. Introducing an appropriate filter into the probe for\nlow-energy photon has proven to improve the response. The dosemeter then satisfies the criteria of the personal dosemeter for\neye lens dosimetry and can be applicable to individual monitoring of eye lens dose. This article also discusses the applicability of\nthe dosemeter to area monitoring for decision making regarding additional monitoring of the eye lens and the extremities.","subitem_description_type":"Abstract"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1093/rpd/ncab009","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://academic.oup.com/rpd/advance-article/doi/10.1093/rpd/ncab009/6138734?searchresult=1","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0144-8420","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Munehiko, Kowatari"}],"nameIdentifiers":[{"nameIdentifier":"1008713","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Zutz, Hayo"}],"nameIdentifiers":[{"nameIdentifier":"1008714","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hupe, Oliver"}],"nameIdentifiers":[{"nameIdentifier":"1008715","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Munehiko, Kowatari","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1008716","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"APPLICABILITY OF A COMMERCIALLY AVAILABLE ACTIVE EXTREMITY DOSE-RATE METER TO EYE LENS DOSE MONITORING","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"APPLICABILITY OF A COMMERCIALLY AVAILABLE ACTIVE EXTREMITY DOSE-RATE METER TO EYE LENS DOSE MONITORING"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-02-18"},"publish_date":"2021-02-18","publish_status":"0","recid":"81878","relation_version_is_last":true,"title":["APPLICABILITY OF A COMMERCIALLY AVAILABLE ACTIVE EXTREMITY DOSE-RATE METER TO EYE LENS DOSE MONITORING"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:11:20.622674+00:00"}