{"created":"2023-05-15T15:00:18.746075+00:00","id":81852,"links":{},"metadata":{"_buckets":{"deposit":"136e53c8-bf39-4c70-a303-791990e16116"},"_deposit":{"created_by":1,"id":"81852","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"81852"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00081852","sets":["1"]},"author_link":["1010031","1010032","1010030","1010029"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2021-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"875","bibliographicPageStart":"869","bibliographicVolumeNumber":"327","bibliographic_titles":[{"bibliographic_title":"Journal of Radioanalytical and Nuclear Chemistry"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Astatine was separated from a lead target, irradiated with 7Li ion beams, by dry distillation. Dry distillation was conducted in a glass test tube filled with nitrogen gas by heating the test tube with an electric furnace at 650 ℃. The optimized conditions of the dry distillation procedure were studied by monitoring astatine radioactivity with gamma-ray spectrometers. The separation of astatine was accomplished in ~10 min. The cooling of the middle portion of the test tube was instrumental in recovering astatine radioactivity in high yields. The adsorption temperature of astatine on the glass surface was ~20 ℃.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Springer Nature"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1007/s10967-020-07546-2","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://link.springer.com/article/10.1007/s10967-020-07546-2","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0236-5731","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Nishinaka, Ichiro"}],"nameIdentifiers":[{"nameIdentifier":"1010029","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hashimoto, Kazuyuki"}],"nameIdentifiers":[{"nameIdentifier":"1010030","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ichiro, Nishinaka","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1010031","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kazuyuki, Hashimoto","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1010032","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Separation of astatine from irradiated lead targets based on dry distillation in a glass test tube","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Separation of astatine from irradiated lead targets based on dry distillation in a glass test tube"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2020-12-11"},"publish_date":"2020-12-11","publish_status":"0","recid":"81852","relation_version_is_last":true,"title":["Separation of astatine from irradiated lead targets based on dry distillation in a glass test tube"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:05:24.361138+00:00"}