{"created":"2023-05-15T14:59:29.011374+00:00","id":80705,"links":{},"metadata":{"_buckets":{"deposit":"13d37393-1b51-40f6-a8a4-a81d44fbb78e"},"_deposit":{"created_by":1,"id":"80705","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"80705"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00080705","sets":["10:28"]},"author_link":["892165","892163","892166","892162","892164","892167","892168","892169"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2020-09-15","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"- Adequate CIRT dose delivery with protection of key OARs in complex H&N cancer appears feasible with the horizontal + coplanar approach. - Dose increase in optic nerves and eyes when near or obstructing tumor from the port were noted. - Increased brain dosage was noted in all cases. The impact of low-dose high-LET CIRT on neural tissue requires further exploration. - Potentials such as sitting-up immobilization for anteroposterior delivery may mitigate the limitations seen here. A larger cohort analysis is in progress.\n","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"American Society for Radiation Oncology (ASTRO) Annual meeting 2020","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Ebner, Daniel"}],"nameIdentifiers":[{"nameIdentifier":"892162","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Koto, Masashi"}],"nameIdentifiers":[{"nameIdentifier":"892163","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Furuichi, Wataru"}],"nameIdentifiers":[{"nameIdentifier":"892164","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mori, Shinichiro"}],"nameIdentifiers":[{"nameIdentifier":"892165","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ebner, Daniel","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"892166","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Koto, Masashi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"892167","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Furuichi, Wataru","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"892168","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mori, Shinichiro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"892169","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Proof-of-Concept Comparative Dosimetric Analysis of Coplanar Horizontal-Port Carbon-Ion Radiotherapy in the Head and Neck","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Proof-of-Concept Comparative Dosimetric Analysis of Coplanar Horizontal-Port Carbon-Ion Radiotherapy in the Head and Neck"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2020-09-08"},"publish_date":"2020-09-08","publish_status":"0","recid":"80705","relation_version_is_last":true,"title":["Proof-of-Concept Comparative Dosimetric Analysis of Coplanar Horizontal-Port Carbon-Ion Radiotherapy in the Head and Neck"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:27:26.391222+00:00"}