{"created":"2023-05-15T14:59:10.636194+00:00","id":80291,"links":{},"metadata":{"_buckets":{"deposit":"f6b71529-f843-4a0e-b447-dc360032f19b"},"_deposit":{"created_by":1,"id":"80291","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"80291"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00080291","sets":["1"]},"author_link":["883591","883593","883599","883600","883589","883597","883595","883590","883592","883598","883596","883594"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2020-06","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"91","bibliographicPageStart":"83","bibliographicVolumeNumber":"74","bibliographic_titles":[{"bibliographic_title":"Physica Medica"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Abstract\nPurpose\nThis study aimed to measure the eye lens doses received by physicians and other medical staff participating in non-vascular imaging and interventional radiology procedures in Japan.\n\nMaterial and methods\nFrom October 2014 to March 2017, 34 physicians and 29 other medical staff engaged in non-vascular imaging and interventional radiology procedures at 18 Japanese medical facilities. These professionals wore radioprotective lead glasses equipped with small, optically stimulated luminescence dosimeters and additional personal dosimeters at the neck during a 1-month monitoring period. The Hp(3) and the Hp(10) and Hp(0.07) were obtained from these devices, respectively. The monthly Hp(3), Hp(10), and Hp(0.07) for each physician and other medical staff member were then rescaled to a 12-month period to enable comparisons with the revised occupational equivalent dose limit for the eye lens.\n\nResults\nAmong physicians, the average annual Hp(3) values measured by the small luminescence dosimeters on radioprotective glasses were 25.5 ± 38.3 mSv/y (range: 0.4–166.8 mSv/y) and 9.3 ± 16.6 mSv/y (range: 0.3–82.4 mSv/y) on the left and right sides, respectively. The corresponding values for other medical staff were 3.7 ± 3.1 mSv/y (range: 0.4–10.4 mSv/y) and 3.2 ± 2.7 mSv/y (range: 0.5–11.5 mSv/y), respectively.\n\nConclusions\nThe eye lens doses incurred by physicians and other medical staff who engaged in non-vascular imaging and interventional radiology procedures in Japan were provided. Physicians should wear radioprotective glasses and use additional radioprotective devices to reduce the amount of eye lens doses they receive.","subitem_description_type":"Abstract"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1016/j.ejmp.2020.05.004","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.sciencedirect.com/science/article/pii/S1120179720301162","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1120-1797","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Matsubara, Kosuke"}],"nameIdentifiers":[{"nameIdentifier":"883589","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takei, Yasutaka"}],"nameIdentifiers":[{"nameIdentifier":"883590","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mori, Hiroshige"}],"nameIdentifiers":[{"nameIdentifier":"883591","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kobayashi, Ikuo"}],"nameIdentifiers":[{"nameIdentifier":"883592","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Noto, Kimiya"}],"nameIdentifiers":[{"nameIdentifier":"883593","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Igarashi, Takayuki"}],"nameIdentifiers":[{"nameIdentifier":"883594","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Suzuki, Shoichi"}],"nameIdentifiers":[{"nameIdentifier":"883595","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Akahane, Keiichi"}],"nameIdentifiers":[{"nameIdentifier":"883596","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Matsubara, Kosuke","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"883597","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kobayashi, Ikuo","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"883598","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Igarashi, Takayuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"883599","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Akahane, Keiichi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"883600","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"A multicenter study of radiation doses to the eye lenses of medical staff performing non-vascular imaging and interventional radiology procedures in Japan","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"A multicenter study of radiation doses to the eye lenses of medical staff performing non-vascular imaging and interventional radiology procedures in Japan"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2020-08-04"},"publish_date":"2020-08-04","publish_status":"0","recid":"80291","relation_version_is_last":true,"title":["A multicenter study of radiation doses to the eye lenses of medical staff performing non-vascular imaging and interventional radiology procedures in Japan"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:37:33.844629+00:00"}